A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System

Dong Hyun Choi iD, Yoon Ha Joo iD, Ki Hong Kim iD, Jeong Ho Park iD, Hyunjin Joo, Hyoun-Joong Kong, Hyunju Lee, Kyoung Jun Song, Sungwan Kim iD

IEEE Journal of Translational Engineering in Health and Medicine · 2024

DOI: 10.1109/jtehm.2024.3433448 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Translational Engineering in Health and Medicine, 2024. Verfasst von Dong Hyun Choi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical EngineeringSeoul National University College of Medicine Jongno Seoul 03080 South Korea. Hauptthemen laut MEDLINE: Cardiopulmonary Resuscitation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Research Foundation of South Korea Grant funded by the Korea Government Ministry of Science and ICT.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The objective of this study was to develop a sound recognition-based cardiopulmonary resuscitation (CPR) training system that is accessible, cost-effective, easy-to-maintain and provides accurate CPR feedback. Beep-CPR, a novel device with accordion squeakers that emit high-pitched sounds during compression, was developed. The sounds emitted by Beep-CPR were recorded using a smartphone, segmented into 2-second audio fragments, and then transformed into spectrograms. A total of 6,065 spectrograms were generated from approximately 40 minutes of audio data, which were then randomly split into training, validation, and test datasets. Each spectrogram was matched with the depth, rate, and release velocity of the compression measured at the same time interval by the ZOLL X Series monitor/defibrillator. Deep learning models utilizing spectrograms as input were trained using transfer learning based on EfficientNet to predict the depth (Depth model), rate (Rate model), and release velocity (Recoil model) of compressions. Results: The mean absolute error (MAE) for the Depth model was 0.30 cm (95% confidence interval [CI]: 0.27-0.33). The MAE of the Rate model was 3.6/min (95% CI: 3.2-3.9). For the Recoil model, the MAE was 2.3 cm/s (95% CI: 2.1-2.5). External validation of the models demonstrated acceptable performance across multiple conditions, including the utilization of a newly-manufactured device, a fatigued device, and evaluation in an environment with altered spatial dimensions. We have developed a novel sound recognition-based CPR training system, that accurately measures compression quality during training. Significance: Beep-CPR is a cost-effective and easy-to-maintain solution that can improve the efficacy of CPR training by facilitating decentralized at-home training with performance feedback.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiopulmonary ResuscitationHumansSoundSound SpectrographySignal Processing, Computer-AssistedDeep LearningSmartphoneEquipment Design

Stichwörter der Autor:innen

Cardiopulmonary arrestdeep learningfeedback communicationssound recognition

Autor:innen und Institutionen

  • Department of Biomedical EngineeringSeoul National University College of Medicine Jongno Seoul 03080 South Korea.
  • Biomedical Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.
  • Department of Emergency MedicineSeoul National University Hospital Jongno Seoul 03080 South Korea.
  • Innovative Medical Technology Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.
  • Department of Transdisciplinary MedicineInnovative Medical Technology Research InstituteSeoul National University Hospital Jongno Seoul 03080 South Korea.
  • Department of MedicineSeoul National University College of Medicine Jongno Seoul 03080 South Korea.

ORCID-Profile: Dong Hyun Choi, Yoon Ha Joo, Ki Hong Kim, Jeong Ho Park, Sungwan Kim

Förderung

  • National Research Foundation of South Korea Grant funded by the Korea Government Ministry of Science and ICT

Zitieren

APA

Hyun Choi, D., Ha Joo, Y., Hong Kim, K., Ho Park, J., Joo, H., Kong, H. J., Lee, H., Jun Song, K., & Kim, S. (2024). A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System. IEEE Journal of Translational Engineering in Health and Medicine. https://doi.org/10.1109/jtehm.2024.3433448

Vancouver

Hyun Choi D, Ha Joo Y, Hong Kim K, Ho Park J, Joo H, Kong HJ, et al. A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System. IEEE Journal of Translational Engineering in Health and Medicine. 2024. doi:10.1109/jtehm.2024.3433448

BibTeX
@article{HyunChoi2024,
  author = {Hyun Choi, Dong and Ha Joo, Yoon and Hong Kim, Ki and Ho Park, Jeong and Joo, Hyunjin and Kong, Hyoun-Joong and Lee, Hyunju and Jun Song, Kyoung and Kim, Sungwan},
  title = {A Development of a Sound Recognition-Based Cardiopulmonary Resuscitation Training System},
  journal = {IEEE Journal of Translational Engineering in Health and Medicine},
  year = {2024},
  doi = {10.1109/jtehm.2024.3433448}
}
Kostenlos starten →