EUVIMEDEUVIMED entdecken
Crossref

A Pt-Ir10 Wire-Wound High-Temperature Strain Gauge for Strain Measurement Up to 1300 °C

Tong Hao, Mingyang Kong, Fan Zhang, Jiaxin Song, Jiahao Yang, Haigang Wang, Haojie Xu, Ruliang Xu, Qianyu Wang, Junsheng Liang

IEEE Sensors Journal · 2026-11 · 26 (21) · 32219-32226

DOI: 10.1109/jsen.2026.3737217 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Tong Hao und 9 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Gefördert von: Aviation Science Fund, Science and Technology Program of Liaoning Province, Shanghai Science and Technology Research and Development Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-temperature strain measurement above $1300~^{\circ }$ C remains challenging because conventional thin-film strain gauges (TFSGs) suffer from oxidation, resistance drift, and long-term instability. Herein, a Pt-Ir10 wire-wound strain gauge was fabricated using a self-developed winding apparatus, and the strain-sensing performance was systematically characterized from room temperature to $1300~^{\circ }$ C. The sensor exhibited a room-temperature gauge factor (GF) of 2.12 and maintained a clear dynamic strain response at $1300~^{\circ }$ C. A 5-h dwell test at $1300~^{\circ }$ C showed an average resistance drift rate of 0.681%/h, and a continuous cyclic loading–unloading test at $1300~^{\circ }$ C for approximately 7 h (about 8000 cycles) was conducted without signal interruption or sensing failure. Under high-temperature conditions, the average GF at $1300~^{\circ }$ C was 1.01. In addition, the influence of grid number on high-temperature sensitivity was investigated. Under the geometric parameters and fabrication process adopted in this work, the five-grid structure exhibited the highest average GF among the investigated configurations. These results demonstrate the feasibility of the Pt-Ir10 wire-wound strain gauge for strain measurement in extreme high-temperature environments.

Förderung

  • Aviation Science Fund
  • Science and Technology Program of Liaoning Province
  • Shanghai Science and Technology Research and Development Program

Zitieren

APA

Hao, T., Kong, M., Zhang, F., Song, J., Yang, J., Wang, H., Xu, H., Xu, R., Wang, Q., & Liang, J. (2026). A Pt-Ir10 Wire-Wound High-Temperature Strain Gauge for Strain Measurement Up to 1300 °C. IEEE Sensors Journal, 26(21), 32219-32226. https://doi.org/10.1109/jsen.2026.3737217

Vancouver

Hao T, Kong M, Zhang F, Song J, Yang J, Wang H, et al. A Pt-Ir10 Wire-Wound High-Temperature Strain Gauge for Strain Measurement Up to 1300 °C. IEEE Sensors Journal. 2026;26(21):32219-32226. doi:10.1109/jsen.2026.3737217

BibTeX
@article{Hao2026,
  author = {Hao, Tong and Kong, Mingyang and Zhang, Fan and Song, Jiaxin and Yang, Jiahao and Wang, Haigang and Xu, Haojie and Xu, Ruliang and Wang, Qianyu and Liang, Junsheng},
  title = {A Pt-Ir10 Wire-Wound High-Temperature Strain Gauge for Strain Measurement Up to 1300 °C},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {32219--32226},
  doi = {10.1109/jsen.2026.3737217}
}
Kostenlos starten →