EUVIMEDEUVIMED entdecken
Crossref

Conformal Corrugated Slow Wave Structures Loaded Dual Resonant Mode Loop Antenna for In Vivo Temperature Sensing in WCE System

Sumon Modak, Vikrant Kaim, Binod Kumar Kanaujia, Alka Verma, Shilpee Patil, Karumudi Rambabu

IEEE Sensors Journal · 2026-11 · 26 (21) · 33331-33344

DOI: 10.1109/jsen.2026.3732606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Sumon Modak und 5 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Gefördert von: Department of Science and Technology (DST), Government of India, through the Biomedical Device and Technology Development Scheme.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article introduces a real-time functional ingestible capsule endoscope system featuring sensing capability, validated through wireless temperature monitoring in a Wistar rat. A capsule-integrated inner wall wrappable, conformal corrugated slow wave structures (CSWSs) loaded dual-mode loop antenna excited by a coplanar feed structure are designed within a muscle-mimicking cubic model for wireless data transfer. Surface current distribution on the impedance-matched notched ground resembles that of the modified loop with its full and half perimeter providing $\lambda _{\text {g}}$ /2 mode resonances at 0.915 (0.9–1.05 GHz) and 2.4 GHz (2.2–2.55 GHz) with quasi-omnidirectional radiation patterns having a total gain of −15.1 and −15.3 dBi, respectively. Electromagnetic interference (EMI) is evaluated by wrapping different shielding layers between the antenna and the enclosed battery. The capsule performance is further analyzed using a human anatomical model, and validation is also extended to a rat model—both simulated in Sim4Life. As per ITU-R RS.1346 guidelines, the dosimetric study in the “Ella”—a human female and rat model qualifies the capsule device as suitable and safe for human use. The capsule device is fabricated and experimentally validated in a muscle-mimicking phantom, minced pork, and a Wistar rat, exhibiting a satisfactory performance at 0.915 and 2.4 GHz. Additionally, in vivo temperature sensing of the Wistar rat is achieved using a DS18B20 sensor interfaced with a software-defined radio (SDR), enabling wireless data transmission at 1- and 25-Mbps data rates to an external receiver. Importantly, the successful demonstration of wireless operation of the implanted capsule system in live animal underscores the practical relevance and translational potential of the proposed capsule system for biomedical applications.

Förderung

  • Department of Science and Technology (DST), Government of India, through the Biomedical Device and Technology Development Scheme

Zitieren

APA

Modak, S., Kaim, V., Kanaujia, B. K., Verma, A., Patil, S., & Rambabu, K. (2026). Conformal Corrugated Slow Wave Structures Loaded Dual Resonant Mode Loop Antenna for In Vivo Temperature Sensing in WCE System. IEEE Sensors Journal, 26(21), 33331-33344. https://doi.org/10.1109/jsen.2026.3732606

Vancouver

Modak S, Kaim V, Kanaujia BK, Verma A, Patil S, Rambabu K. Conformal Corrugated Slow Wave Structures Loaded Dual Resonant Mode Loop Antenna for In Vivo Temperature Sensing in WCE System. IEEE Sensors Journal. 2026;26(21):33331-33344. doi:10.1109/jsen.2026.3732606

BibTeX
@article{Modak2026,
  author = {Modak, Sumon and Kaim, Vikrant and Kanaujia, Binod Kumar and Verma, Alka and Patil, Shilpee and Rambabu, Karumudi},
  title = {Conformal Corrugated Slow Wave Structures Loaded Dual Resonant Mode Loop Antenna for In Vivo Temperature Sensing in WCE System},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {33331--33344},
  doi = {10.1109/jsen.2026.3732606}
}
Kostenlos starten →