ECGGo: Design and HRV Validation of a Low-Cost ECG-Centered Multimodal Wearable Platform for Physiological Monitoring

Premchand Premchand, Jayant Kalra, Satyanarayanan R. Nadar, Ayush Arya, Sahil Sankhyan, Varun Dutt

IEEE Sensors Journal · 2026-11 · 26 (21) · 33305-33313

DOI: 10.1109/jsen.2026.3732048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von Premchand Premchand und 5 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Gefördert von: Applied Cognitive Science Laboratory, Indian Institute of Technology Mandi, Kamand, India, Prof. Varun Dutt and IITM/iHub & HCIF-IIT Mandi/AP/423 to Prof. Amit Prasad.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable physiological monitoring outside clinical settings requires affordable, multimodal devices with sufficient accuracy for heart rate variability (HRV) assessment. Consumer photoplethysmography (PPG) devices are susceptible to motion artifacts, whereas research-grade electrocardiography (ECG) systems remain costly. ECGGo is an RP2040-based wearable (~USD 50 bill-of-materials (BoM)) measuring ECG, peripheral oxygen saturation (SpO ${}_{2}$ ), galvanic skin response, nine-axis motion, and skin-surface temperature. ECG signals are acquired at 512 Hz (18-bit) using a MAX30003 analog front-end and processed on a smartphone using Butterworth filtering, Pan–Tompkins R-peak detection, artifact screening, and time-domain HRV extraction. Core HRV metrics (mean NNI, SDNN, RMSSD, and SDSD) were validated against a Shimmer3 ECG system in 44 resting participants, achieving absolute errors $\le 1.31$ ms, Pearson correlations of 0.985–0.999, and no significant device differences. In 16 participants, resting heart rate and SpO 2 were similarly indistinguishable from a clinical pulse oximeter. The coefficient-of-variation metrics CVSD and CVNNI yielded lower correlations ( $r =0.39$ and 0.34, respectively), reflecting the known sensitivity of these indices to short recording epochs. In a 10-day single-subject feasibility demonstration (not a formal validation), ECGGo showed plausible day-to-day activity concordance with a Fitbit Sense 2 ( $r =0.94$ ), with multiparticipant validation planned as future work. GSR, skin temperature, frequency-domain HRV, and ambulatory monitoring are implemented but not included in the present validation and are scoped as future work. The reported cost reflects the bill of materials only. ECGGo provides a practical, low-cost platform for reference-validated resting ECG-derived HRV monitoring, with multimodal sensing supporting future field-based physiological research.

Förderung

  • Applied Cognitive Science Laboratory, Indian Institute of Technology Mandi, Kamand, India
  • Prof. Varun Dutt and IITM/iHub & HCIF-IIT Mandi/AP/423 to Prof. Amit Prasad

Zitieren

APA

Premchand, P., Kalra, J., Nadar, S. R., Arya, A., Sankhyan, S., & Dutt, V. (2026). ECGGo: Design and HRV Validation of a Low-Cost ECG-Centered Multimodal Wearable Platform for Physiological Monitoring. IEEE Sensors Journal, 26(21), 33305-33313. https://doi.org/10.1109/jsen.2026.3732048

Vancouver

Premchand P, Kalra J, Nadar SR, Arya A, Sankhyan S, Dutt V. ECGGo: Design and HRV Validation of a Low-Cost ECG-Centered Multimodal Wearable Platform for Physiological Monitoring. IEEE Sensors Journal. 2026;26(21):33305-33313. doi:10.1109/jsen.2026.3732048

BibTeX
@article{Premchand2026,
  author = {Premchand, Premchand and Kalra, Jayant and Nadar, Satyanarayanan R. and Arya, Ayush and Sankhyan, Sahil and Dutt, Varun},
  title = {ECGGo: Design and HRV Validation of a Low-Cost ECG-Centered Multimodal Wearable Platform for Physiological Monitoring},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {33305--33313},
  doi = {10.1109/jsen.2026.3732048}
}
Kostenlos starten →