EUVIMEDEUVIMED entdecken
Crossref

Tantalum Nitride and Titanium Nitride Thin-Film Extended-Gate Field-Effect Transistor-Based pH Sensors for Chemically Challenging Media: A Controlled Comparative Study

K. Sivanagireddy, M. V. R. Vittal, Swetha M. S., Subha Subramaniam, K. V. Balaramakrishna, Rayapati Venkata Sudhakar, Babu Rajendra Prasad D, Muzammil Parvez M

IEEE Sensors Journal · 2026-11 · 26 (21) · 32099-32106

DOI: 10.1109/jsen.2026.3727650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-11. Verfasst von K. Sivanagireddy und 7 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This work presents a controlled same-platform benchmark of tantalum nitride (TaN) and titanium nitride (TiN) thin films as extended-gate field-effect transistor (EGFET) pH-sensing membranes for chemically challenging aqueous media. Although TiN-based EGFET pH sensors have been widely reported, a direct TaN/TiN comparison under identical fabrication, encapsulation, conditioning, biasing, and measurement conditions remains limited. TaN and TiN films with matched thickness and sensing-window geometry were evaluated in the same EGFET architecture over pH 2–12 using five independently fabricated devices for each membrane. Both sensors exhibited near-Nernstian response, with sensitivities of ${58.8} \pm {0.4}$ mV/pH ( $\textit {R}^{{2}}={0.997}$ ) for TaN and ${57.4} \pm {0.5}$ mV/pH ( $\textit {R}^{{2}}={0.996}$ ) for TiN. Compared with TiN, TaN showed faster response/recovery ( $\sim {18}/{19}$ s versus $\sim {24}/{23}$ s), lower hysteresis ( ${2.1} \pm {0.3}$ mV versus $3.3 \pm 0.4$ mV), lower 72 h drift ( ${1.3} \pm {0.25}$ mV versus ${6.2} \pm {0.34}$ mV), smaller interference-induced deviations, and better agreement with laboratory pH-meter values in effluent/wastewater samples. Atomic force microscopy (AFM) confirmed continuous nanoscale morphology, X-ray photoelectron spectroscopy (XPS) verified mixed nitride/oxynitride/oxide surface chemistry with hydroxyl-related species, and electrochemical impedance spectroscopy (EIS) fitting using $\textit {R}_{\textit {s}}{\,}-{\,}(\textit {R}_{\text {ct}}\parallel \text {CPE})$ yielded a higher $\textit {R}_{\text {ct}}$ for TaN ( ${386.2} \pm {5.6}~\Omega $ ) than for TiN ( ${161.3} \pm {7.8}~\Omega $ ). The results identify TaN as a more stable conductive nitride membrane than the TiN benchmark under the tested EGFET pH-sensing conditions, while extended field validation remains necessary for long-term harsh-environment deployment.

Zitieren

APA

Sivanagireddy, K., Vittal, M. V. R., S., S. M., Subramaniam, S., Balaramakrishna, K. V., Sudhakar, R. V., D, B. R. P., & M, M. P. (2026). Tantalum Nitride and Titanium Nitride Thin-Film Extended-Gate Field-Effect Transistor-Based pH Sensors for Chemically Challenging Media: A Controlled Comparative Study. IEEE Sensors Journal, 26(21), 32099-32106. https://doi.org/10.1109/jsen.2026.3727650

Vancouver

Sivanagireddy K, Vittal MVR, S. SM, Subramaniam S, Balaramakrishna KV, Sudhakar RV, et al. Tantalum Nitride and Titanium Nitride Thin-Film Extended-Gate Field-Effect Transistor-Based pH Sensors for Chemically Challenging Media: A Controlled Comparative Study. IEEE Sensors Journal. 2026;26(21):32099-32106. doi:10.1109/jsen.2026.3727650

BibTeX
@article{Sivanagireddy2026,
  author = {Sivanagireddy, K. and Vittal, M. V. R. and S., Swetha M. and Subramaniam, Subha and Balaramakrishna, K. V. and Sudhakar, Rayapati Venkata and D, Babu Rajendra Prasad and M, Muzammil Parvez},
  title = {Tantalum Nitride and Titanium Nitride Thin-Film Extended-Gate Field-Effect Transistor-Based pH Sensors for Chemically Challenging Media: A Controlled Comparative Study},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {32099--32106},
  doi = {10.1109/jsen.2026.3727650}
}
Kostenlos starten →