EUVIMEDEUVIMED entdecken
Crossref

A TiO 2 -Au Dual-Coated PCF-SPR Sensor for Multi-Ion Detection of Blood Electrolytes

Md. Ashraful Alam Tamim, Dil Mahfuzur Rahman, Rummanur Rahad, Jishu Prasad Das, Md. Shakibur Rahman

IEEE Sensors Journal · 2026-08 · 26 (16) · 23635-23642

DOI: 10.1109/jsen.2026.3710894 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-08. Verfasst von Md. Ashraful Alam Tamim und 4 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate and continuous monitoring of blood electrolyte concentrations remains a critical challenge in point-of-care diagnostics, particularly in resource-limited settings where conventional techniques are impractical. In this work, a $\text {TiO}_{{2}}$ –gold dual-coated photonic crystal fiber-based surface plasmon resonance (PCF-SPR) sensor is proposed for the label-free detection of major blood electrolytes, including $\text {Na}^{+}, \text {K}^{+}, \text {Ca}^{{2}+}$ , and $\text {Mg}^{{2}+}$ ions. The optimized design achieves a high wavelength sensitivity of up to 3500 nm/RIU and an amplitude sensitivity of $401.734~\text {RIU}^{-{1}}$ , enabling precise detection within clinically relevant ranges. The inclusion of a $\text {TiO}_{{2}}$ interlayer enhances plasmonic coupling efficiency and improves the mechanical stability of the gold film. To the best of our knowledge, this is the first PCF-SPR sensor systematically designed for the detection of all four major blood electrolyte ions within a single platform, offering a promising pathway toward compact, high-sensitivity, and label-free optical biosensors for next-generation point-of-care applications.

Zitieren

APA

Tamim, M. A. A., Rahman, D. M., Rahad, R., Das, J. P., & Rahman, M. S. (2026). A TiO 2 -Au Dual-Coated PCF-SPR Sensor for Multi-Ion Detection of Blood Electrolytes. IEEE Sensors Journal, 26(16), 23635-23642. https://doi.org/10.1109/jsen.2026.3710894

Vancouver

Tamim MAA, Rahman DM, Rahad R, Das JP, Rahman MS. A TiO 2 -Au Dual-Coated PCF-SPR Sensor for Multi-Ion Detection of Blood Electrolytes. IEEE Sensors Journal. 2026;26(16):23635-23642. doi:10.1109/jsen.2026.3710894

BibTeX
@article{Tamim2026,
  author = {Tamim, Md. Ashraful Alam and Rahman, Dil Mahfuzur and Rahad, Rummanur and Das, Jishu Prasad and Rahman, Md. Shakibur},
  title = {A TiO 2 -Au Dual-Coated PCF-SPR Sensor for Multi-Ion Detection of Blood Electrolytes},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {16},
  pages = {23635--23642},
  doi = {10.1109/jsen.2026.3710894}
}
Kostenlos starten →