EUVIMEDEUVIMED entdecken
Crossref

Electrochemical Detection of Piroxicam Using a CuMo/LDH@Phosphorus-Doped Reduced Graphene Oxide Modified Electrode

Sedigheh Parvaz, Zahra Kasiri Baboukani, Ali A. Ensafi, Kimia Zarean Mousaabadi

IEEE Sensors Journal · 2026-08 · 26 (16) · 23562-23573

DOI: 10.1109/jsen.2026.3707009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-08. Verfasst von Sedigheh Parvaz und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel electrochemical sensor was developed for the sensitive determination of piroxicam based on a 3-D phosphorus-doped reduced graphene oxide (PrGO) supported CuMo layered double hydroxide (LDH) nanocomposite (CuMo/LDH@PrGO). The electroactive material was synthesized via an in situ approach and immobilized onto a glassy carbon electrode to enhance the electrocatalytic oxidation of piroxicam. Comprehensive physicochemical characterization of the prepared nanocomposite was performed using field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), and X-ray diffraction (XRD), BET surface area analysis, and Raman spectroscopy. The electrochemical performance of the proposed sensor was systematically optimized. A well-defined oxidation peak with an increasing current response was observed with increasing piroxicam concentration. Under optimal conditions, the sensor exhibited two linear dynamic ranges from 0.02 to $10~\mu $ M and 10- $60~\mu $ M, with a low limit of detection (LOD) of 6.2 nM. The proposed sensor demonstrated good repeatability, stability, and selectivity, with negligible interference from common metal ions (Fe ${}^{\mathbf {{2}+}}$ , Cu ${}^{\mathbf {{2}+}}$ , Zn ${}^{\mathbf {{2}+}}$ , SO ${}_{\mathbf {{4}}}^{\mathbf {{2}-}}$ , and NO ${}_{\mathbf {{3}}}^{-}$ ) and coexisting electroactive species such as folic acid, dopamine, and ascorbic acid. Finally, the applicability of the sensor was successfully evaluated for the determination of piroxicam in real samples, including human plasma, urine, and pharmaceutical tablet formulations.

Zitieren

APA

Parvaz, S., Baboukani, Z. K., Ensafi, A. A., & Mousaabadi, K. Z. (2026). Electrochemical Detection of Piroxicam Using a CuMo/LDH@Phosphorus-Doped Reduced Graphene Oxide Modified Electrode. IEEE Sensors Journal, 26(16), 23562-23573. https://doi.org/10.1109/jsen.2026.3707009

Vancouver

Parvaz S, Baboukani ZK, Ensafi AA, Mousaabadi KZ. Electrochemical Detection of Piroxicam Using a CuMo/LDH@Phosphorus-Doped Reduced Graphene Oxide Modified Electrode. IEEE Sensors Journal. 2026;26(16):23562-23573. doi:10.1109/jsen.2026.3707009

BibTeX
@article{Parvaz2026,
  author = {Parvaz, Sedigheh and Baboukani, Zahra Kasiri and Ensafi, Ali A. and Mousaabadi, Kimia Zarean},
  title = {Electrochemical Detection of Piroxicam Using a CuMo/LDH@Phosphorus-Doped Reduced Graphene Oxide Modified Electrode},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {16},
  pages = {23562--23573},
  doi = {10.1109/jsen.2026.3707009}
}
Kostenlos starten →