EUVIMEDEUVIMED entdecken
Crossref

Carbon Electrodes Coupled With Paper-Based Microfluidics for Simultaneous Electrochemical Detection of Cadmium and Lead

Jinkyeong Kim, Woo-Jin Song, Chang-Mo Kang, Daewoong Jung, Joonhyub Kim

IEEE Sensors Journal · 2026-08 · 26 (15) · 22128-22135

DOI: 10.1109/jsen.2026.3705853 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-08. Verfasst von Jinkyeong Kim und 4 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a low-cost and portable electrochemical sensing platform was developed by integrating a paper-based microfluidic channel with a screen-printed three-electrode system on a flexible polyethylene terephthalate (PET) substrate. The device enabled selective and quantitative detection of cadmium (Cd 2+ ) and lead (Pb 2+ ). To improve cadmium sensitivity, an ex situ modification strategy was applied by incorporating an Sb 2 O 3 precursor into the carbon paste. Systematic evaluation of the electrochemical performance as a function of Sb content showed that the electrode containing 5 wt% Sb 2 O 3 exhibited the highest Cd stripping current, corresponding to an approximately 2.18-fold increase compared with that of the pristine carbon electrode. The microfluidic channel was fabricated via wax printing followed by thermal treatment, and the channel geometry was optimized based on the Washburn capillary flow model. Cyclic voltammetry (CV) using the Fe(CN) 6 ${}^{3-/4-}$ redox probe demonstrated quasi-reversible behavior with a peak-to-peak separation ( $\boldsymbol {\Delta \textit {E}_{\textit {p}}}$ ) of 78 mV, indicating diffusion-controlled electron transfer. Under optimized deposition conditions ( $\mathbf {-{1}.{3}}$ V for 600 s), square-wave anodic stripping voltammetry (ASV) yielded linear detection ranges of 20– $1500~\boldsymbol {\mu }$ g/L for both metals. The limits of detection were $1~\boldsymbol {\mu }$ g/L for Cd 2+ and $3~\boldsymbol {\mu }$ g/L for Pb 2+ . Minimal interference was observed, except for Cu–Pb alloy formation.

Zitieren

APA

Kim, J., Song, W., Kang, C., Jung, D., & Kim, J. (2026). Carbon Electrodes Coupled With Paper-Based Microfluidics for Simultaneous Electrochemical Detection of Cadmium and Lead. IEEE Sensors Journal, 26(15), 22128-22135. https://doi.org/10.1109/jsen.2026.3705853

Vancouver

Kim J, Song W, Kang C, Jung D, Kim J. Carbon Electrodes Coupled With Paper-Based Microfluidics for Simultaneous Electrochemical Detection of Cadmium and Lead. IEEE Sensors Journal. 2026;26(15):22128-22135. doi:10.1109/jsen.2026.3705853

BibTeX
@article{Kim2026,
  author = {Kim, Jinkyeong and Song, Woo-Jin and Kang, Chang-Mo and Jung, Daewoong and Kim, Joonhyub},
  title = {Carbon Electrodes Coupled With Paper-Based Microfluidics for Simultaneous Electrochemical Detection of Cadmium and Lead},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {15},
  pages = {22128--22135},
  doi = {10.1109/jsen.2026.3705853}
}
Kostenlos starten →