Auto-Calibrated Handheld Microwave Thermometer With Low-Noise and Enhanced EMI Immunity for Deep Tissue Sensing
IEEE Sensors Journal · 15.07.2026 · 26 (14) · 21024-21032
DOI: 10.1109/jsen.2026.3701828 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.07.2026. Verfasst von Neenu Vymeliyath Sajeev und 1 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Anusandhan National Research Foundation, Government of India, TDK Corporation, Japan.
Abstract (Originalsprache)
A handheld low-noise and high-gain microwave radiometer operating over 2.7–3.1 GHz with excellent immunity to ambient electromagnetic (EM) interference is presented for passive tissue thermometry. A dual-reference switch circulator Dicke configuration was implemented to realize a handheld sensing device with auto-calibration capability for compensating measurement instabilities. Full-wave EM simulations of the multilayer printed circuit board (PCB) were carried out to design a field-deployable handheld radiometer with reduced circuit parasitic, transmission line loss, and crosstalk. Furthermore, a custom metal enclosure was designed to improve the radiated immunity of the hand-held radiometer. The fabricated miniaturized radiometer ( $70\times 50$ mm2) has a 50 dB gain, a very low noise figure (NF) of 1.01 dB at 3 GHz, −3 dB bandwidth of 408 MHz, and thermal sensitivity of 0.30 K. Radiometer measurements demonstrated system stability, immunity to external EM interference (EMI) and, ability to auto-calibrate thermal measurements for large variations in the sensor input impedance. Measurements also indicated better thermal sensitivity than the conventional single reference Dicke radiometer, thereby demonstrating its potential for field deployment for passive deep tissue thermometry.
Förderung
- Anusandhan National Research Foundation, Government of India
- TDK Corporation, Japan
Zitieren
APA
Sajeev, N. V., & Arunachalam, K. (2026). Auto-Calibrated Handheld Microwave Thermometer With Low-Noise and Enhanced EMI Immunity for Deep Tissue Sensing. IEEE Sensors Journal, 26(14), 21024-21032. https://doi.org/10.1109/jsen.2026.3701828
Vancouver
Sajeev NV, Arunachalam K. Auto-Calibrated Handheld Microwave Thermometer With Low-Noise and Enhanced EMI Immunity for Deep Tissue Sensing. IEEE Sensors Journal. 2026;26(14):21024-21032. doi:10.1109/jsen.2026.3701828
BibTeX
@article{Sajeev2026,
author = {Sajeev, Neenu Vymeliyath and Arunachalam, Kavitha},
title = {Auto-Calibrated Handheld Microwave Thermometer With Low-Noise and Enhanced EMI Immunity for Deep Tissue Sensing},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {14},
pages = {21024--21032},
doi = {10.1109/jsen.2026.3701828}
}
EUVIMED