EUVIMEDEUVIMED entdecken
Crossref

MOF-Derived Ni/NiO on Cu Foam Electrode Modified for Selective and Ultrasensitive Electrochemical Creatinine Detection

Syed Momina Sultana, Shital Jyostna Sahoo, Manaswini Ravipati, Sushmee Badhulika

IEEE Sensors Journal · 15.07.2026 · 26 (14) · 20620-20626

DOI: 10.1109/jsen.2026.3695569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.07.2026. Verfasst von Syed Momina Sultana und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Creatinine is a clinically important biomarker for renal function assessment. Abnormally low levels may reflect muscle degradation, whereas elevated levels are associated with underlying kidney dysfunction. Therefore, accurate monitoring is essential for early detection and disease management. In this study, we report a novel metal–organic framework (MOF)-derived Ni/NiO heterostructure, synthesized via a solvothermal route, integrated onto a copper foam (CF) electrode, for sensing creatinine in sweat samples. The formation of Ni/NiO heterostructures is evident from the SEM characterization, providing a high density of accessible electroactive sites. Fourier transform infrared (FTIR) spectrum gives vibrational features associated with Ni–O bonding. Optimization studies of Ni/NiO@CF electrode (7 wt.%, pH 7.2) are performed in the window 0.4–1.6 V versus Hg∣HgO, and improved electron-transfer rates and electrode kinetics are obtained by electrochemical impedance spectroscopy (EIS). The DPV analysis demonstrates detection of creatinine with a wide linear response range ( $0.01-100 ~\mu \mathrm{M}$ ) [R2 = 0.99], ultrahigh sensitivity ( $ 6.2 ~\mu \mathrm{A} \cdot \mu \mathrm{M}^{-1}{\!}\cdot{\!} \mathrm{~cm}^{-2}$ ), and an impressively low detection limit (0.306 nM), making it suitable for noninvasive trace-level analysis. The sensor exhibits excellent performance, satisfactory operational stability, and reproducibility with recovery values of 99.96%, along with outstanding selectivity against common sweat interferents such as dopamine, glucose, urea, and uric acid. Finally, the practicality of the sensor is validated by quantifying creatinine in simulated human sweat samples, establishing its potential for future wearable point-of-care (POC) applications in personalized health monitoring.

Zitieren

APA

Sultana, S. M., Sahoo, S. J., Ravipati, M., & Badhulika, S. (2026). MOF-Derived Ni/NiO on Cu Foam Electrode Modified for Selective and Ultrasensitive Electrochemical Creatinine Detection. IEEE Sensors Journal, 26(14), 20620-20626. https://doi.org/10.1109/jsen.2026.3695569

Vancouver

Sultana SM, Sahoo SJ, Ravipati M, Badhulika S. MOF-Derived Ni/NiO on Cu Foam Electrode Modified for Selective and Ultrasensitive Electrochemical Creatinine Detection. IEEE Sensors Journal. 2026;26(14):20620-20626. doi:10.1109/jsen.2026.3695569

BibTeX
@article{Sultana2026,
  author = {Sultana, Syed Momina and Sahoo, Shital Jyostna and Ravipati, Manaswini and Badhulika, Sushmee},
  title = {MOF-Derived Ni/NiO on Cu Foam Electrode Modified for Selective and Ultrasensitive Electrochemical Creatinine Detection},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {20620--20626},
  doi = {10.1109/jsen.2026.3695569}
}
Kostenlos starten →