Conformal Single-Port Microwave Biosensor for Contactless Dielectric Liquid Characterization
IEEE Sensors Journal · 01.07.2026 · 26 (13) · 19635-19644
DOI: 10.1109/jsen.2026.3692650 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.07.2026. Verfasst von Benyamin Harkinezhad und 5 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Gefördert von: KU Leuven, Fonds Wetenschappelijk Onderzoek (FWO) funding, KU Leuven-University of Melbourne Joint Ph.D. Program.
Abstract (Originalsprache)
This article presents a flexible, one-port microwave biosensor for contactless permittivity characterization of biological and chemical samples based on waveguide mode excitation. Unlike conventional resonator-based or multiport microwave sensors, which rely on resonance tracking or transmission measurements, the proposed sensor operates using a single-port reflection measurement and exploits the excitation and recoupling of a waveguide mode within the material under test (MUT). The proposed sensor employs a cylindrical coplanar waveguide (CCPW) wrapped around standard laboratory glass test tubes to excite a waveguide mode within the MUT without direct contact. The underlying coupling mechanism is analyzed using field overlap considerations, and its manifestation in the measured reflection coefficient is examined. The excitation and recoupling of the waveguide mode give rise to characteristic loop features in the S11 response, which are shown to be strongly dependent on the real and imaginary parts of the sample permittivity. A dedicated de-embedding procedure is introduced to isolate the intrinsic sensor response using a single reference measurement. The sensor performance is experimentally validated through measurements on aqueous solutions of ethanol, NaCl, glucose, and yeast. Sensitivity metrics derived from the extracted loop parameters demonstrate minimum sensitivities of 14.1 MHz per unit $\epsilon_r^{\prime}$ and 0.21 per unit tanδ. In addition, the sensor exhibits good repeatability, with maximum standard deviations of 0.0054 in magnitude and 7.52° in phase across repeated measurements up to 5 GHz. The results highlight a sensing approach that combines contactless operation, simplified measurement, and high sensitivity, offering a compelling alternative to existing microwave biosensing techniques.
Förderung
- KU Leuven
- Fonds Wetenschappelijk Onderzoek (FWO) funding
- KU Leuven-University of Melbourne Joint Ph.D. Program
Zitieren
APA
Harkinezhad, B., Markovic, T., Evans, R., Ghorbani, K., Skafidas, E., & Schreurs, D. (2026). Conformal Single-Port Microwave Biosensor for Contactless Dielectric Liquid Characterization. IEEE Sensors Journal, 26(13), 19635-19644. https://doi.org/10.1109/jsen.2026.3692650
Vancouver
Harkinezhad B, Markovic T, Evans R, Ghorbani K, Skafidas E, Schreurs D. Conformal Single-Port Microwave Biosensor for Contactless Dielectric Liquid Characterization. IEEE Sensors Journal. 2026;26(13):19635-19644. doi:10.1109/jsen.2026.3692650
BibTeX
@article{Harkinezhad2026,
author = {Harkinezhad, Benyamin and Markovic, Tomislav and Evans, Robin and Ghorbani, Kamran and Skafidas, Efstratios and Schreurs, Dominique},
title = {Conformal Single-Port Microwave Biosensor for Contactless Dielectric Liquid Characterization},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {13},
pages = {19635--19644},
doi = {10.1109/jsen.2026.3692650}
}
EUVIMED