EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams

M. Ponzecchi, K. Kanxheri, L. Servoli, M. V. Rossi, E. Gazzera, G. Insero, S. Pallotta, M. Fabi, C. Grimani, F. Sabbatini, M. Villani, S. Aziz und 28 weitere

IEEE Sensors Journal · 15.06.2026 · 26 (12) · 18356-18365

DOI: 10.1109/jsen.2026.3689750 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.06.2026. Verfasst von M. Ponzecchi und 39 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HASPIDE project funded by Istituto Nazionale di Fisica Nucleare (INFN) through the CSN5, Swiss National Science Foundation, PANDORA project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible hydrogenated amorphous silicon (a-Si:H) detectors are attractive candidates for clinical dosimetry, particularly for applications requiring lightweight devices and operation without external bias. In this work, three flexible a-Si:H detector architectures are experimentally compared under clinical photon and electron beams: a conventional n-i-p diode, a charge selective contact (CSC) detector, and a very thin p-i-n diode. All detectors show excellent dose linearity under both irradiation modalities. However, large differences in sensitivity are observed at zero bias, exceeding two orders of magnitude across architectures. The conventional n-i-p device shows a response that is limited by the internal electric field, while CSC and very thin p-i-n detectors achieve sensitivities in the pC/cGy range without applied bias. Electron beams yield higher charge per unit dose than photons, compatible with a larger local energy deposition in the active layer. The results demonstrate that sensitivity in flexible a-Si:H dosimeters is governed by contact design and intrinsic layer thickness rather than by active volume alone. Taken together, the present results suggest that combining CSCs with thinner intrinsic layers may represent a promising strategy to further enhance zero-bias sensitivity. These findings provide clear design guidelines for the development of flexible dosimeters for surface and transmission measurements in advanced radiotherapy (RT).

Förderung

  • HASPIDE project funded by Istituto Nazionale di Fisica Nucleare (INFN) through the CSN5
  • Swiss National Science Foundation
  • PANDORA project

Zitieren

APA

Ponzecchi, M., Kanxheri, K., Servoli, L., Rossi, M. V., Gazzera, E., Insero, G., Pallotta, S., Fabi, M., Grimani, C., Sabbatini, F., Villani, M., Aziz, S., Calcagnile, L., Caricato, A. P., Martino, M., Maruccio, G., Monteduro, A. G., Quarta, G., Rizzato, S., …, & Cesare, G. D. (2026). Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams. IEEE Sensors Journal, 26(12), 18356-18365. https://doi.org/10.1109/jsen.2026.3689750

Vancouver

Ponzecchi M, Kanxheri K, Servoli L, Rossi MV, Gazzera E, Insero G, et al. Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams. IEEE Sensors Journal. 2026;26(12):18356-18365. doi:10.1109/jsen.2026.3689750

BibTeX
@article{Ponzecchi2026,
  author = {Ponzecchi, M. and Kanxheri, K. and Servoli, L. and Rossi, M. V. and Gazzera, E. and Insero, G. and Pallotta, S. and Fabi, M. and Grimani, C. and Sabbatini, F. and Villani, M. and Aziz, S. and Calcagnile, L. and Caricato, A. P. and Martino, M. and Maruccio, G. and Monteduro, A. G. and Quarta, G. and Rizzato, S. and Catalano, R. and Cirrone, G. A. P. and Cuttone, G. and Guarrera, M. and Petringa, G. and Frontini, L. and Liberali, V. and Stabile, A. and Vasquez, M. M. S. and Cittadini, F. and Croci, T. and Ionica, M. and Menichelli, M. and Morozzi, A. and Passeri, D. and Pedio, M. and Peverini, F. and Placidi, P. and Zema, N. and Caputo, D. and Cesare, G. de},
  title = {Characterization of Hydrogenated Amorphous Silicon Detectors With Clinical Photon and Electron Beams},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {18356--18365},
  doi = {10.1109/jsen.2026.3689750}
}
Kostenlos starten →