EUVIMEDEUVIMED entdecken
Crossref

A Differential-Rotation Dual-Probe Field Mill for DC Total Electric Field Measurement

Zhenghai Liao, Jiangong Zhang, Zheyuan Gan, Xingfa Liu, Jun Zhao, Baoquan Wan, Hao Wan, Yemao Zhang

IEEE Sensors Journal · 15.06.2026 · 26 (12) · 18116-18126

DOI: 10.1109/jsen.2026.3687166 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.06.2026. Verfasst von Zhenghai Liao und 7 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Hubei Provincial Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

DC total electric field measurement under highvoltage direct current (HVDC) transmission lines suffers from inherent challenges of electric field distortion caused by sensor grounding and interference from corona ions. To address these issues, this article develops a ground-free differentialrotation dual-probe field mill. The sensor consists of two identically structured split-cylinder probes coaxially mounted on a common motor shaft but operating at different rotational speeds, together with peripheral signal processing circuits. Each probe comprises multiple fan-shaped cylindrical metal mantles with uniform dimensions, a motor, a photodetector integrated with a grating and a slot-type photoelectric sensor, and a slip ring. Four key innovations are incorporated. Corona discharge tips on the mantle surface enable potential clamping via charge leakage. Multifan-shaped cylindrical metal mantles enhance electric field measurement sensitivity and resolution. Dual probes with differential signal processing suppress corona ion interference. A dedicated hardware circuit performs weak signal conditioning, polarity discrimination, and signal output. The field mill was comprehensively validated using laboratory calibration systems, reduced-scale conductor models, and field tests on the ±800 kV UHVDC Zhalute–Guanggu transmission line. Laboratory results demonstrate excellent linear response in ion-containing electric fields, with relative deviations from simulated values within ±2.15% under corona conditions, matching the accuracy of conventional shutter-type field mills. Field measurements show consistent trends with traditional devices in both perpendicular and parallel cross sections of the transmission line, confirming stable operation in engineering environments. These results verify that the proposed field mill effectively mitigates grounding-induced distortion and corona ion interference, meeting the requirements of engineering applications. The main limitation is slightly inferior measurement repeatability compared to shutter-type field mills, and future work will focus on optimizing probe rotation stability and signal processing algorithms to improve measurement consistency, thereby facilitating broader application in electromagnetic environment evaluation of HVDC transmission lines.

Förderung

  • Hubei Provincial Natural Science Foundation of China

Zitieren

APA

Liao, Z., Zhang, J., Gan, Z., Liu, X., Zhao, J., Wan, B., Wan, H., & Zhang, Y. (2026). A Differential-Rotation Dual-Probe Field Mill for DC Total Electric Field Measurement. IEEE Sensors Journal, 26(12), 18116-18126. https://doi.org/10.1109/jsen.2026.3687166

Vancouver

Liao Z, Zhang J, Gan Z, Liu X, Zhao J, Wan B, et al. A Differential-Rotation Dual-Probe Field Mill for DC Total Electric Field Measurement. IEEE Sensors Journal. 2026;26(12):18116-18126. doi:10.1109/jsen.2026.3687166

BibTeX
@article{Liao2026,
  author = {Liao, Zhenghai and Zhang, Jiangong and Gan, Zheyuan and Liu, Xingfa and Zhao, Jun and Wan, Baoquan and Wan, Hao and Zhang, Yemao},
  title = {A Differential-Rotation Dual-Probe Field Mill for DC Total Electric Field Measurement},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {18116--18126},
  doi = {10.1109/jsen.2026.3687166}
}
Kostenlos starten →