P-MAPS: A Custom-Topology Velostat Insole for Pressure Redistribution in Diabetic Foot Care
IEEE Sensors Journal · 01.06.2026 · 26 (11) · 16764-16774
DOI: 10.1109/jsen.2026.3684148 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2026. Verfasst von Andres Osorio Salazar und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Innosuisse-Swiss Innovation Agency Program.
Themen: Diabetisches Fußsyndrom
Abstract (Originalsprache)
Diabetic foot ulcers (DFUs) remain a major complication of diabetes mellitus, with significant human and economic costs. Plantar pressure (PP) is the most widely used surrogate to assess DFU risk. Existing PP measurement insoles are primarily designed for in-clinic assessments using external instrumentation to guide passive offloading strategies. However, reliance on brief clinical measurements limits their ability to capture real-world loading patterns, motivating the development of sensing systems capable of continuous monitoring and integration within pressure-management footwear. Such systems require spatially discretized sensing elements fully embedded within the shoe architecture. This work presents the design and characterization of P-MAPS (Plantar-Monitoring Au-Plated Pressure System), a custom-topology pressure-sensing insole co-designed for precise spatial alignment with offloading elements. The sensor uses the piezoresistive response of Velostat combined with gold-plated electrodes to improve uniformity and repeatability. The device exhibits a measurement range of 45–350 kPa, a coefficient of variation below 2.5%, normalized hysteresis of 25.8%, and 6% drift after 5 min. Dynamic gait validation against a commercial reference (Pedar, Novel) demonstrated accurate peak-pressure estimation with 2.6% error under full spatial overlap, while enabling localized pressure measurement over actuated regions and revealing that sensing areas not co-located with actuator regions can misrepresent local pressures due to spatial averaging effects. These results establish P-MAPS as a robust and practical sensing solution for continuous, footwear-integrated plantar-pressure monitoring and adaptive offloading applications.
Förderung
- Innosuisse-Swiss Innovation Agency Program
Zitieren
APA
Salazar, A. O., Dagon, M., Germano, P., Koechli, C., Pataky, Z., Civet, Y., & Perriard, Y. (2026). P-MAPS: A Custom-Topology Velostat Insole for Pressure Redistribution in Diabetic Foot Care. IEEE Sensors Journal, 26(11), 16764-16774. https://doi.org/10.1109/jsen.2026.3684148
Vancouver
Salazar AO, Dagon M, Germano P, Koechli C, Pataky Z, Civet Y, et al. P-MAPS: A Custom-Topology Velostat Insole for Pressure Redistribution in Diabetic Foot Care. IEEE Sensors Journal. 2026;26(11):16764-16774. doi:10.1109/jsen.2026.3684148
BibTeX
@article{Salazar2026,
author = {Salazar, Andres Osorio and Dagon, Maël and Germano, Paolo and Koechli, Christian and Pataky, Zoltan and Civet, Yoan and Perriard, Yves},
title = {P-MAPS: A Custom-Topology Velostat Insole for Pressure Redistribution in Diabetic Foot Care},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {11},
pages = {16764--16774},
doi = {10.1109/jsen.2026.3684148}
}