EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simulation for Noncontact Radar-Based Respiratory Measurement Using Depth Camera-Derived Human 3-D Models

Kimitaka Sumi, Takuya Sakamoto

IEEE Sensors Journal · 01.06.2026 · 26 (11) · 17742-17757

DOI: 10.1109/jsen.2026.3683864 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2026. Verfasst von Kimitaka Sumi und 1 weiteren Autor:innen. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SECOM Science and Technology Foundation, Japan Science and Technology Agency, Japan Society for the Promotion of Science KAKENHI.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a simulation framework is proposed that serves as a foundation for improving the accuracy of human vital sensing using millimeter-wave radar. Unlike conventional approaches that rely on simplified models of body geometry or displacement, the proposed method simulates the signals received by frequency-modulated continuous-wave (FMCW) radar during respiratory monitoring using realistic human body shapes and motions acquired via a depth camera. Furthermore, the proposed method enables fast data generation by using time-averaged human body geometry and discrete scattering centers. Experiments were conducted on six participants under varying conditions, including varying target distances, seating orientations, and radar types, with simultaneous acquisition from radar and the depth camera. Relative to conventional model-based methods, the proposed technique achieved improvements of 7.6%, 58.7%, and 3.7% in the correlation coefficients of radar images, displacements, and spectrograms, respectively. This work contributes to the generation of radar-based physiological datasets through simulation and enhances our understanding of factors that affect the accuracy of noncontact sensing.

Förderung

  • SECOM Science and Technology Foundation
  • Japan Science and Technology Agency
  • Japan Society for the Promotion of Science KAKENHI
  • New Energy and Industrial Technology Development Organization

Zitieren

APA

Sumi, K., & Sakamoto, T. (2026). Simulation for Noncontact Radar-Based Respiratory Measurement Using Depth Camera-Derived Human 3-D Models. IEEE Sensors Journal, 26(11), 17742-17757. https://doi.org/10.1109/jsen.2026.3683864

Vancouver

Sumi K, Sakamoto T. Simulation for Noncontact Radar-Based Respiratory Measurement Using Depth Camera-Derived Human 3-D Models. IEEE Sensors Journal. 2026;26(11):17742-17757. doi:10.1109/jsen.2026.3683864

BibTeX
@article{Sumi2026,
  author = {Sumi, Kimitaka and Sakamoto, Takuya},
  title = {Simulation for Noncontact Radar-Based Respiratory Measurement Using Depth Camera-Derived Human 3-D Models},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {11},
  pages = {17742--17757},
  doi = {10.1109/jsen.2026.3683864}
}