EUVIMEDEUVIMED entdecken
Crossref

A Compact PCB-Integrated Inductive Six-Axis Force/Torque Sensor

Hyun-Bin Kim, Kyung-Soo Kim

IEEE Sensors Journal · 01.06.2026 · 26 (11) · 16717-16729

DOI: 10.1109/jsen.2026.3683368 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2026. Verfasst von Hyun-Bin Kim und 1 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korean Government [Ministry of Science and ICT (MSIT)].

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a compact six-axis force/torque (F/T) sensor based on inductive displacement measurement with full PCB integration of sensing and electronics. A flexure structure and conductive target plate are co-designed with multilayer planar and vertical coils so that each wrench component produces a distinct inductive response. Finite-element analysis yields a 6 × 6 stiffness matrix that guides the flexure geometry, resulting in a sensor with 85-mm diameter, 36-mm height, and ranges of ±890 N $(F_{x}, F_{y})$ , ±1435 N $(F_{z})$ , ±27 ${\mathrm {N}} \cdot {\mathrm {m}} (T_{x}, T_{y}$ ), and ±45 ${\mathrm {N}} \cdot {\mathrm {m}} (T_{z})$ . The coil array is interfaced to an inductance-to-digital converter (LDC) and a microcontroller on the same PCB, providing real-time F/T estimates via a controller area network flexible data-rate (CAN-FD) interface at up to 4 kHz without external data-acquisition hardware. The nonlinear mapping between the six-channel inductance readings and the applied wrench is identified experimentally. Several candidate models are compared, including linear, polynomial, sigmoid, Gaussian, and rational functions; a constrained rational model achieves the lowest fitting error (root mean square error (RMSE) 0.0009, linearity error 0.11%) with only five parameters and is adopted for calibration. Static experiments against a commercial six-axis F/T sensor show maximum full-scale errors of 0.64% in force and 0.75% in torque, with low cross-axis coupling and up to 55 351 quantization levels. Drop-impact tests demonstrate reliable dynamic tracking of the reference sensor over 1–200 Hz, with a mean coherence of 0.963. Under BLDC motor/inverter and Wi-Fi/RF interference, the normalized noise increase remains below 4% and 15.1%, respectively, indicating that the proposed inductive platform maintains stable performance for embedded robotic joint and end-effector sensing.

Förderung

  • National Research Foundation of Korea
  • Korean Government [Ministry of Science and ICT (MSIT)]

Zitieren

APA

Kim, H., & Kim, K. (2026). A Compact PCB-Integrated Inductive Six-Axis Force/Torque Sensor. IEEE Sensors Journal, 26(11), 16717-16729. https://doi.org/10.1109/jsen.2026.3683368

Vancouver

Kim H, Kim K. A Compact PCB-Integrated Inductive Six-Axis Force/Torque Sensor. IEEE Sensors Journal. 2026;26(11):16717-16729. doi:10.1109/jsen.2026.3683368

BibTeX
@article{Kim2026,
  author = {Kim, Hyun-Bin and Kim, Kyung-Soo},
  title = {A Compact PCB-Integrated Inductive Six-Axis Force/Torque Sensor},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {11},
  pages = {16717--16729},
  doi = {10.1109/jsen.2026.3683368}
}
Kostenlos starten →