EUVIMEDEUVIMED entdecken
Crossref

Unidirectional Saturation in Closed-Loop Self-Oscillating Fluxgate Current Sensors: Analysis, Recovery Method, and Circuit Design

Xiaoguang Yang, Yujie Lu, Shuhuan Gao, Xuebiao Li

IEEE Sensors Journal · 15.05.2026 · 26 (10) · 15202-15210

DOI: 10.1109/jsen.2026.3680963 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.05.2026. Verfasst von Xiaoguang Yang und 3 weiteren Autor:innen. Gefördert von: Science and Technology (S&T) Program of Hebei.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Closed-loop self-oscillating fluxgate current sensors are prone to driving their magnetic cores into unidirectional saturation under conditions such as loaded start-up, overload operation, or an excessively high rate of change in the measured current. This saturation induces a “pseudo-zero-flux” state, which locks the system and impedes its recovery to the true zero-flux equilibrium, a critical problem that cannot be effectively solved by traditional saturation recovery schemes. To address this issue, this article first analyzes the operating characteristics of the sensor under unidirectional saturation. Subsequently, a saturation recovery method with a corresponding implementation circuit is proposed, which incorporates an auxiliary feedback loop. When unidirectional saturation occurs, the proposed method dynamically detects the output polarity of the proportional-integral (PI) controller and adjusts it to match the direction of the measured current. This intervention forces the system to exit the unidirectional saturation state and restore the true zero-flux balance. The proposed scheme features a simpler hardware architecture and smoother state transition compared with traditional solutions, without additional complex circuits or interruption to normal measurement. An experimental prototype was fabricated based on the proposed method and circuit. Test results validate the correctness of the theoretical analysis and confirm the effectiveness of the proposed method and circuit, which can reliably achieve loaded start-up and overload recovery, and effectively solve the “pseudo-zero-flux” lock-up problem of this type of sensor.

Förderung

  • Science and Technology (S&T) Program of Hebei

Zitieren

APA

Yang, X., Lu, Y., Gao, S., & Li, X. (2026). Unidirectional Saturation in Closed-Loop Self-Oscillating Fluxgate Current Sensors: Analysis, Recovery Method, and Circuit Design. IEEE Sensors Journal, 26(10), 15202-15210. https://doi.org/10.1109/jsen.2026.3680963

Vancouver

Yang X, Lu Y, Gao S, Li X. Unidirectional Saturation in Closed-Loop Self-Oscillating Fluxgate Current Sensors: Analysis, Recovery Method, and Circuit Design. IEEE Sensors Journal. 2026;26(10):15202-15210. doi:10.1109/jsen.2026.3680963

BibTeX
@article{Yang2026,
  author = {Yang, Xiaoguang and Lu, Yujie and Gao, Shuhuan and Li, Xuebiao},
  title = {Unidirectional Saturation in Closed-Loop Self-Oscillating Fluxgate Current Sensors: Analysis, Recovery Method, and Circuit Design},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {15202--15210},
  doi = {10.1109/jsen.2026.3680963}
}