Robust Wearable Motion Recognition Using a Two-Stage FMG Pipeline With Rest Filtering and Placement Adaptation
IEEE Sensors Journal · 01.07.2026 · 26 (13) · 19492-19503
DOI: 10.1109/jsen.2026.3674514 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.07.2026. Verfasst von Ye-Jin Lee und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Korea Institute of Machinery and Materials, Digital Medical Products Development Based on Medical Data Synthesis and AI Technologies Program, Ministry of Trade, Industry and Resources (MOTIR) of Korea.
Abstract (Originalsprache)
Wearable force myography (FMG) sensors enable continuous motion monitoring through mechanical interaction with soft tissue, but their practical deployment is challenged by rest-related signal ambiguity and placementinduced variability. This study proposes a two-stage action discriminator–action classifier (ADAC) pipeline that explicitly separates rest-dominant segments from motion-related signals and applies domain-adaptive inference to mitigate placement-induced distribution shifts. Using a lightweight two-channel air-bladder cuff sensor, the ADAC pipeline achieves stable motion recognition under realistic wearing conditions. Under unified cross-participant evaluation with pooled multi subject data, the proposed framework demonstrates an overall accuracy (ACC) of 94.9% and an F1-score of 87.9% using cuff-only sensing, without requiring subject-specific calibration. Compared with conventional FMG systems that rely on dense sensing configurations or peruser recalibration, the ADAC pipeline achieves robust performance using only two pressure channels through integrated rest-aware filtering and placement-adaptive classification. These results demonstrate the feasibility of lightweight cufftype FMG sensors for continuous motion recognition in real-world, multi user scenarios and underscore the importance of system-level design in pressure-based wearable sensing.
Förderung
- Korea Institute of Machinery and Materials
- Digital Medical Products Development Based on Medical Data Synthesis and AI Technologies Program
- Ministry of Trade, Industry and Resources (MOTIR) of Korea
Zitieren
APA
Lee, Y., Kim, K. T., Oh, K., & Lee, K. (2026). Robust Wearable Motion Recognition Using a Two-Stage FMG Pipeline With Rest Filtering and Placement Adaptation. IEEE Sensors Journal, 26(13), 19492-19503. https://doi.org/10.1109/jsen.2026.3674514
Vancouver
Lee Y, Kim KT, Oh K, Lee K. Robust Wearable Motion Recognition Using a Two-Stage FMG Pipeline With Rest Filtering and Placement Adaptation. IEEE Sensors Journal. 2026;26(13):19492-19503. doi:10.1109/jsen.2026.3674514
BibTeX
@article{Lee2026,
author = {Lee, Ye-Jin and Kim, Kyoung Tae and Oh, Keonyoung and Lee, Kang-Ho},
title = {Robust Wearable Motion Recognition Using a Two-Stage FMG Pipeline With Rest Filtering and Placement Adaptation},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {13},
pages = {19492--19503},
doi = {10.1109/jsen.2026.3674514}
}
EUVIMED