EUVIMEDEUVIMED entdecken
Crossref

A Novel IMU-Based Joint Angle Calculation With Robust Joint Axis Estimation via PCA

Seoyoon Hwang, Jonghyun Kim

IEEE Sensors Journal · 01.05.2026 · 26 (9) · 13785-13795

DOI: 10.1109/jsen.2026.3670757 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.05.2026. Verfasst von Seoyoon Hwang und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Technology Innovation Program, Development of an Integrated Rehabilitation Platform Based on Artificial Intelligence and Multimodal Interaction for Personalized Upper Limb Dysfunction Traini…, Ministry of Trade, Industry & Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Inertial measurement units (IMUs) have been used for motion analysis, but accurate joint angle estimation requires alignment between each sensor frame and the anatomical segment. To avoid explicit sensor–segment alignment, we estimate the joint axis directly from data. We introduce PCA-3S, principal component analysis (PCA)-based joint axis estimation with sample selection scheme that extracts single-degree-of-freedom (DoF) segments from multi-DoF-contaminated calibration data. PCA-3S is designed to address the limitations of conventional PCA methods, which are sensitive to multi-DoF motion contamination during calibration. Using the estimated axes, joint angles are obtained via an axis-based rotation matrix decomposition that reduces calibration burden. We evaluate the method on an elbow apparatus and human subject data under varying contamination levels, speeds, and sensor misalignments. PCA-3S achieves consistent axis errors of 6.1° for flexion/extension and 3.1° for supination/pronation on the apparatus, with joint angle root-mean-square errors (RMSEs) below 5.0°. Human elbow experiments yielded RMSEs of approximately 8.5°, outperforming conventional PCA and optimization approaches. These results indicate that PCA-3S provides robust, accurate joint axis and joint angle estimation suitable for unconstrained environments.

Förderung

  • Technology Innovation Program
  • Development of an Integrated Rehabilitation Platform Based on Artificial Intelligence and Multimodal Interaction for Personalized Upper Limb Dysfunction Traini…
  • Ministry of Trade, Industry & Energy

Zitieren

APA

Hwang, S., & Kim, J. (2026). A Novel IMU-Based Joint Angle Calculation With Robust Joint Axis Estimation via PCA. IEEE Sensors Journal, 26(9), 13785-13795. https://doi.org/10.1109/jsen.2026.3670757

Vancouver

Hwang S, Kim J. A Novel IMU-Based Joint Angle Calculation With Robust Joint Axis Estimation via PCA. IEEE Sensors Journal. 2026;26(9):13785-13795. doi:10.1109/jsen.2026.3670757

BibTeX
@article{Hwang2026,
  author = {Hwang, Seoyoon and Kim, Jonghyun},
  title = {A Novel IMU-Based Joint Angle Calculation With Robust Joint Axis Estimation via PCA},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {13785--13795},
  doi = {10.1109/jsen.2026.3670757}
}
Kostenlos starten →