Real-Time Headspace O 2 Sensing in Pharmaceutical Vials by Light-Intensity-Compensated WMS-TDLAS
IEEE Sensors Journal · 2026-04 · 26 (8) · 11788-11795
DOI: 10.1109/jsen.2026.3669099 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, 2026-04. Verfasst von Xiyue Wang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Project of Jinhua City.
Abstract (Originalsprache)
In this study, a real-time detection system for residual oxygen in the headspace of medicine vials based on wavelength modulation-tunable diode laser absorption spectroscopy (WMS-TDLAS) technology was developed. Aiming at the absorption characteristics of oxygen near 760 nm, an analog automatic gain control (AGC) circuit with a voltagecontrolled gain amplifier (VGA) as the core is designed to realize real-time light intensity compensation and effectively suppress the influence of light source fluctuation and transmission interference on the second harmonic signal. The system can compensate up to 81% of the light intensity attenuation, the compensation relative error is less than 2%, and the dynamic response time is less than 1.337 s. In the concentration calibration test, the output signal of the system has a good linear relationship with the oxygen concentration, and the fitting determination coefficient R2 is 0.996. Under different light intensity attenuation conditions, the maximum standard deviation of the peak-to-peak value of the compensated signal is 0.017 V, and the maximum relative standard deviation is 0.753%, which proves that it has excellent robustness. It meets the requirements of rapid and high-precision real-time detection of headspace residual oxygen in glass vials, and provides a reliable real-time detection solution for headspace residual oxygen in the pharmaceutical industry.
Förderung
- National Natural Science Foundation of China
- Science and Technology Project of Jinhua City
Zitieren
APA
Wang, X., Wu, H., Zhang, X., Li, R., Chen, D., Shao, J., & Liu, W. (2026). Real-Time Headspace O 2 Sensing in Pharmaceutical Vials by Light-Intensity-Compensated WMS-TDLAS. IEEE Sensors Journal, 26(8), 11788-11795. https://doi.org/10.1109/jsen.2026.3669099
Vancouver
Wang X, Wu H, Zhang X, Li R, Chen D, Shao J, et al. Real-Time Headspace O 2 Sensing in Pharmaceutical Vials by Light-Intensity-Compensated WMS-TDLAS. IEEE Sensors Journal. 2026;26(8):11788-11795. doi:10.1109/jsen.2026.3669099
BibTeX
@article{Wang2026,
author = {Wang, Xiyue and Wu, Huakun and Zhang, Xuecheng and Li, Renyu and Chen, Daru and Shao, Jie and Liu, Wen},
title = {Real-Time Headspace O 2 Sensing in Pharmaceutical Vials by Light-Intensity-Compensated WMS-TDLAS},
journal = {IEEE Sensors Journal},
year = {2026},
volume = {26},
number = {8},
pages = {11788--11795},
doi = {10.1109/jsen.2026.3669099}
}
EUVIMED