EUVIMEDEUVIMED entdecken
Crossref

Athermalization Design for SOI Waveguide Bragg Grating Photonic Blood Glucose Sensors

Hongqiang Li, Junqu Zhang, Xiaolin Li, Ming Han, Lizhen Zhang, Yueting Yang, Kangming Xu, Lu Cao, Enbang Li

IEEE Sensors Journal · 01.04.2026 · 26 (7) · 10033-10041

DOI: 10.1109/jsen.2026.3664641 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.04.2026. Verfasst von Hongqiang Li und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Project of Natural Science Foundation of Tianjin, Key Research and Development Program of Tianjin.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate monitoring of the blood glucose concentration is critically important for the diagnosis, treatment, and long-term management of diabetes. In this article, an optical blood glucose sensing method is proposed on the basis of silicon-based waveguide Bragg grating (WBG). This method involves the reaction between glucose oxidase (GOD) fixed on the cladding of the waveguide and glucose, which causes a local refractive index change, resulting in a shift in the WBG reflection center wavelength, enabling the quantitative detection of blood glucose concentration. Nevertheless, during measurement, optical blood glucose sensors are susceptible to spectral drifts caused by environmental temperature variations, leading to a decrease in sensing accuracy. To address this issue, a silicon-on-insulator (SOI) WBG sensor for glucose concentration measurement is proposed and implemented. Two types of WBG blood glucose sensors, namely, bilateral and slit sensors, are designed, incorporating an athermalization design to enhance system stability and environmental robustness. By employing a compensating material with a negative thermo-optic coefficient (TOC) and optimizing various waveguide structural parameters, temperature-induced drift is effectively suppressed, which enables the design of bilateral and slit WBG glucose sensors with both glucose sensing and temperature compensation capabilities. The experimental results show that the bilateral WBG glucose sensor exhibits a refractive index sensitivity of 161 nm/refractive index unit (RIU) and a temperature sensitivity of 7.27 pm/°C within a glucose concentration range of 0–2.6 mg/mL. The slit WBG glucose sensor has a refractive index sensitivity of 242.3 nm/RIU and a temperature sensitivity of 2.37 pm/°C within the 0–2.8 mg/mL glucose concentration range.

Förderung

  • National Natural Science Foundation of China
  • Key Project of Natural Science Foundation of Tianjin
  • Key Research and Development Program of Tianjin
  • Open Project of Tianjin Key Laboratory of Optoelectronic Detection Technology and System

Zitieren

APA

Li, H., Zhang, J., Li, X., Han, M., Zhang, L., Yang, Y., Xu, K., Cao, L., & Li, E. (2026). Athermalization Design for SOI Waveguide Bragg Grating Photonic Blood Glucose Sensors. IEEE Sensors Journal, 26(7), 10033-10041. https://doi.org/10.1109/jsen.2026.3664641

Vancouver

Li H, Zhang J, Li X, Han M, Zhang L, Yang Y, et al. Athermalization Design for SOI Waveguide Bragg Grating Photonic Blood Glucose Sensors. IEEE Sensors Journal. 2026;26(7):10033-10041. doi:10.1109/jsen.2026.3664641

BibTeX
@article{Li2026,
  author = {Li, Hongqiang and Zhang, Junqu and Li, Xiaolin and Han, Ming and Zhang, Lizhen and Yang, Yueting and Xu, Kangming and Cao, Lu and Li, Enbang},
  title = {Athermalization Design for SOI Waveguide Bragg Grating Photonic Blood Glucose Sensors},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {10033--10041},
  doi = {10.1109/jsen.2026.3664641}
}
Kostenlos starten →