EUVIMEDEUVIMED entdecken
Crossref

Fiber Bragg Gratings Sensor System for Kinematic and Dynamic Assessment in Lower Limb Robotic Rehabilitation

Pedro Lorenzutti, João Alexandre Coimbra, Rafael Menegardo, Luis Mayag, Edson Souza, Eliton Morais, Anselmo Frizera, Camilo Diaz, Arnaldo Leal-Junior

IEEE Sensors Journal · 01.06.2025 · 25 (11) · 19275-19281

DOI: 10.1109/jsen.2025.3559976 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2025. Verfasst von Pedro Lorenzutti und 8 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Council for Scientific and Technological Development, Fundação de Amparo à Pesquisa e Inovação do Espírito Santo, Ministry of Science and Technology of Brazil (MCTI)/Fundo Nacional de Desenvolvimento Científico e Tecnológico (FNDCT)/Financiadora de estudos e projetos.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents the development and application of a fiber Bragg grating (FBG)-based sensor system for dynamic and kinematics assessment of an exoskeleton for lower limb rehabilitation. The exoskeleton has 2 degree-of-freedom, one at the knee joint and the other for the ankle joint, which is positioned on a chair for robotic-assisted rehabilitation of both joints. The proposed FBG-based sensor system includes an FBG array for the strain distribution assessment along the exoskeleton structure, which is used for the human-robot interaction assessment. In addition, FBG accelerometers and inclinometers are positioned on the knee and ankle joints (respectively) of the exoskeleton for the kinematic analysis of such device. The angle characterization tests indicated a root mean squared error (RMSE) for angle assessment of 3.17° and 1.64° for knee and ankle joints, respectively, which results in a relative errors of 3.96% and 6.07% considering the range of movement of both joints. Moreover, the strain sensors indicated a determination coefficient of 0.999 for FBGs 1 and 2. Thereafter, the sensor system is applied on the knee and ankle joint angle measurements as well as the human-robot interaction via strain distribution along the structure. In this case, the tests with a user indicate the variations in knee and ankle joints within the range of movement applied by the exoskeleton’s controller. Furthermore, the interaction forces between the user and the exoskeleton are evaluated using the strain distribution along the exoskeleton structure.

Förderung

  • National Council for Scientific and Technological Development
  • Fundação de Amparo à Pesquisa e Inovação do Espírito Santo
  • Ministry of Science and Technology of Brazil (MCTI)/Fundo Nacional de Desenvolvimento Científico e Tecnológico (FNDCT)/Financiadora de estudos e projetos
  • European Union under the REFRESH—Research Excellence For REgion Sustainability and High-Tech Industries via the Operational Program Just Transition

Zitieren

APA

Lorenzutti, P., Coimbra, J. A., Menegardo, R., Mayag, L., Souza, E., Morais, E., Frizera, A., Diaz, C., & Leal-Junior, A. (2025). Fiber Bragg Gratings Sensor System for Kinematic and Dynamic Assessment in Lower Limb Robotic Rehabilitation. IEEE Sensors Journal, 25(11), 19275-19281. https://doi.org/10.1109/jsen.2025.3559976

Vancouver

Lorenzutti P, Coimbra JA, Menegardo R, Mayag L, Souza E, Morais E, et al. Fiber Bragg Gratings Sensor System for Kinematic and Dynamic Assessment in Lower Limb Robotic Rehabilitation. IEEE Sensors Journal. 2025;25(11):19275-19281. doi:10.1109/jsen.2025.3559976

BibTeX
@article{Lorenzutti2025,
  author = {Lorenzutti, Pedro and Coimbra, João Alexandre and Menegardo, Rafael and Mayag, Luis and Souza, Edson and Morais, Eliton and Frizera, Anselmo and Diaz, Camilo and Leal-Junior, Arnaldo},
  title = {Fiber Bragg Gratings Sensor System for Kinematic and Dynamic Assessment in Lower Limb Robotic Rehabilitation},
  journal = {IEEE Sensors Journal},
  year = {2025},
  volume = {25},
  number = {11},
  pages = {19275--19281},
  doi = {10.1109/jsen.2025.3559976}
}
Kostenlos starten →