EUVIMEDEUVIMED entdecken
Crossref

Precision Multiband Terahertz Metamaterial Biosensor With Targeted Spectral Selectivity for Early Detection of MCF-7 Breast Cancer Cells

Musa N. Hamza, Mohammad Alibakhshikenari, Bal S. Virdee, Sunil Lavadiya, Iftikhar Ud Din, Bruno Cavalcante de Souza Sanches, Slawomir Koziel, Syeda Iffat Naqvi, Abinash Panda, Ali Farmani, Nasr Rashid, Lida Kouhalvandi und 1 weitere

IEEE Sensors Journal · 01.05.2025 · 25 (9) · 14970-14987

DOI: 10.1109/jsen.2025.3545789 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.05.2025. Verfasst von Musa N. Hamza und 12 weiteren Autor:innen. Die Arbeit wurde bisher 48-mal zitiert (Crossref) und nennt 90 Literaturangaben. Gefördert von: Icelandic Research Fund, National Science Centre of Poland.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cancer remains one of the leading causes of mortality worldwide, with breast cancer (BC) being a particularly prevalent form. Projections estimate nearly 20 million new cases globally over the next two decades. Early detection is critical for effective treatment; however, conventional diagnostic techniques often lack the necessary sensitivity and specificity, with some methods being invasive and labor-intensive. Recent advancements in microwave imaging (MWI) have shown significant potential as efficient, noninvasive tools for monitoring various cancer types. MWI operating in the terahertz (THz) range has emerged as a promising approach for biosensing, offering the precision needed to differentiate between healthy and cancerous tissues by analyzing small-scale biological features. Among the methods for BC detection, the identification and analysis of MCF-7 BC cells are particularly significant. THz waves interact uniquely with the intrinsic properties of MCF-7 cells, making THz-based biosensors ideal candidates for diagnostic tools. However, many existing sensors are limited in key performance areas, including operating bandwidth and absorption efficiency. This study introduces a novel multiband metamaterial (MTM)-based biosensor specifically designed for the detection of MCF-7 BC cells. The sensor features a compact geometry composed of multiple resonators made from 200-nm-thick aluminum (Al) layers on a 50- $\mu $ m-thick polyethylene terephthalate (PET) substrate. With dimensions of only $198\times 198~\mu $ m2, the proposed device is exceptionally compact. It operates in the 0.5–1.6-THz frequency range and achieves near-perfect absorption rates (>99%) across multiple bandwidths. These results are achieved through precise tuning of the sensor’s geometry and architectural optimization, significantly enhancing its sensitivity for cancer detection. Comprehensive validation of the sensor is performed using full-wave electromagnetic analysis, which includes evaluating electric field (E-field) and magnetic field (H-field) distributions, surface currents, and scattering parameters. Extensive benchmarking demonstrates the device’s superior performance compared to state-of-the-art biosensors, excelling in metrics such as quality factor (Q-factor), figure of merit (FOM), and absorption efficiency. In addition, the proposed sensor has been integrated into an MWI system to evaluate its practical application. The device successfully discriminated against subtle changes in the refractive index (RI) of biological tissues, confirming its ability to detect MCF-7 cells effectively. These findings highlight the sensor’s suitability as a noninvasive, early stage diagnostic tool for BC.

Förderung

  • Icelandic Research Fund
  • National Science Centre of Poland

Zitieren

APA

Hamza, M. N., Alibakhshikenari, M., Virdee, B. S., Lavadiya, S., Din, I. U., Sanches, B. C. D. S., Koziel, S., Naqvi, S. I., Panda, A., Farmani, A., Rashid, N., Kouhalvandi, L., & Shariatifar, M. (2025). Precision Multiband Terahertz Metamaterial Biosensor With Targeted Spectral Selectivity for Early Detection of MCF-7 Breast Cancer Cells. IEEE Sensors Journal, 25(9), 14970-14987. https://doi.org/10.1109/jsen.2025.3545789

Vancouver

Hamza MN, Alibakhshikenari M, Virdee BS, Lavadiya S, Din IU, Sanches BCDS, et al. Precision Multiband Terahertz Metamaterial Biosensor With Targeted Spectral Selectivity for Early Detection of MCF-7 Breast Cancer Cells. IEEE Sensors Journal. 2025;25(9):14970-14987. doi:10.1109/jsen.2025.3545789

BibTeX
@article{Hamza2025,
  author = {Hamza, Musa N. and Alibakhshikenari, Mohammad and Virdee, Bal S. and Lavadiya, Sunil and Din, Iftikhar Ud and Sanches, Bruno Cavalcante de Souza and Koziel, Slawomir and Naqvi, Syeda Iffat and Panda, Abinash and Farmani, Ali and Rashid, Nasr and Kouhalvandi, Lida and Shariatifar, Milad},
  title = {Precision Multiband Terahertz Metamaterial Biosensor With Targeted Spectral Selectivity for Early Detection of MCF-7 Breast Cancer Cells},
  journal = {IEEE Sensors Journal},
  year = {2025},
  volume = {25},
  number = {9},
  pages = {14970--14987},
  doi = {10.1109/jsen.2025.3545789}
}
Kostenlos starten →