EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multilevel Signal Quality Assessment Approach for Multichannel Noncontact Smart Mattress Systems

Xin Tan, Yongwen Huang, Ke Xu, Di Zhang, Chenyun Dai, Dong Zhao

IEEE Sensors Journal · 01.09.2025 · 25 (17) · 33447-33459

DOI: 10.1109/jsen.2024.3486781 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.09.2025. Verfasst von Xin Tan und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cross-Disciplinary Research Fund Project of Shanghai Ninth People’s Hospital.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrocardiogram (ECG) is crucial for sleep monitoring, requiring a convenient signal acquisition system and precise signal quality assessment methods in clinical applications. However, traditional ECG acquisition techniques face challenges in capturing signals during sleep. Wet electrodes of traditional contact-based ECG are uncomfortable, and the complex electrode arrangement of the standard 12-lead ECG is user-unfriendly. Moreover, traditional binary annotation strategies and signal quality recognition methods lack comprehensive and accurate analyses. To address this challenge, we designed two distinct multichannel ECG acquisition systems using capacitive-coupled and flexible dry electrodes, integrating them into two different noncontact smart mattresses. For the two-channel acquisition system, we conducted a short-term simulated sleep experiment involving four constrained sleeping postures. For the eight-channel acquisition system, we conducted an overnight real-time sleep experiment under unconstrained sleeping postures. To ensure precise signal quality assessment, we proposed tailored annotation strategies and recognition methods for each sleep monitoring experiment. Using the random forest (RF) approach with 26 signal features, we built a four-level classification model for the simulated sleep experiment and a regression model with discrete numerical ratings for the real-time sleep experiment. The result of the classification model achieved an average accuracy of 81.0% and an average acceptable overlap accuracy (AOA) of 99.1%. The result of the regression model achieved an average acceptable prediction interval coverage probability (APICP) under a 2-Off deviation of 90.2%. Compared with existing methods, the proposed model demonstrated superior performance. This study offers great potential for more convenient and effective sleep monitoring with refined acquisition systems and signal quality assessment methods.

Förderung

  • Cross-Disciplinary Research Fund Project of Shanghai Ninth People’s Hospital

Zitieren

APA

Tan, X., Huang, Y., Xu, K., Zhang, D., Dai, C., & Zhao, D. (2025). Multilevel Signal Quality Assessment Approach for Multichannel Noncontact Smart Mattress Systems. IEEE Sensors Journal, 25(17), 33447-33459. https://doi.org/10.1109/jsen.2024.3486781

Vancouver

Tan X, Huang Y, Xu K, Zhang D, Dai C, Zhao D. Multilevel Signal Quality Assessment Approach for Multichannel Noncontact Smart Mattress Systems. IEEE Sensors Journal. 2025;25(17):33447-33459. doi:10.1109/jsen.2024.3486781

BibTeX
@article{Tan2025,
  author = {Tan, Xin and Huang, Yongwen and Xu, Ke and Zhang, Di and Dai, Chenyun and Zhao, Dong},
  title = {Multilevel Signal Quality Assessment Approach for Multichannel Noncontact Smart Mattress Systems},
  journal = {IEEE Sensors Journal},
  year = {2025},
  volume = {25},
  number = {17},
  pages = {33447--33459},
  doi = {10.1109/jsen.2024.3486781}
}
Kostenlos starten →