Combined Truncated Sidelobe Suppression and Iterative Adaptive MAP Beamforming for Ultrasound Imaging
IEEE Sensors Journal · 15.12.2024 · 24 (24) · 41563-41571
DOI: 10.1109/jsen.2024.3486735 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.12.2024. Verfasst von Lin Tong und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Chongqing Natural Science Foundation.
Abstract (Originalsprache)
In ultrasound (US) plane-wave (PW) imaging, the delay and sum (DAS) beamformer, which is essentially a maximum likelihood estimator, is unable to utilize the a priori information of the signal, resulting in limited image quality, such as a wide main lobe and clutter artifacts. In this article, based on the maximum a posteriori (MAP) framework, we present the iterative adaptive MAP (iAMAP) method beamformer. This method adaptively adjusts the output according to the signal-to-noise ratio (SNR), achieving a good tradeoff between high contrast and scattering preservation performance with low complexity. Considering one drawback of the MAP framework, which struggles to eliminate high sidelobe noise, we employ a truncated sidelobe suppression (TSS) framework to estimate the distribution of the sidelobe noise of the PW signal. This allows for adaptive truncation of weak under noise, avoiding subsequent erroneous suppression of the speckle background. Finally, the TSS is combined with iAMAP to obtain the final beamformer (TiAMAP), to obtain a tradeoff between resolution and contrast, as well as speckle preservation. The results show that, compared with the DAS, the full-width at half-maximum (FWHM) of the TiAMAP for point targets was reduced by an average of 36.53% and 64.71% in simulations and experiments, respectively. The corresponding contrast ratio (CR) improved by an average of 552.38% in simulations and 348.45% in experiments. The TiAMAP method effectively suppresses clutter in the carotid artery and breast cysts, providing better imaging quality. In conclusion, the proposed method can effectively enhance image resolution and CR while maintaining low computational complexity.
Förderung
- National Natural Science Foundation of China
- Chongqing Natural Science Foundation
Zitieren
APA
Tong, L., Shen, Y., Wang, P., Shi, X., Wang, K., Wang, P., & Zhou, X. (2024). Combined Truncated Sidelobe Suppression and Iterative Adaptive MAP Beamforming for Ultrasound Imaging. IEEE Sensors Journal, 24(24), 41563-41571. https://doi.org/10.1109/jsen.2024.3486735
Vancouver
Tong L, Shen Y, Wang P, Shi X, Wang K, Wang P, et al. Combined Truncated Sidelobe Suppression and Iterative Adaptive MAP Beamforming for Ultrasound Imaging. IEEE Sensors Journal. 2024;24(24):41563-41571. doi:10.1109/jsen.2024.3486735
BibTeX
@article{Tong2024,
author = {Tong, Lin and Shen, Yue and Wang, Ping and Shi, Xinwang and Wang, Kunlin and Wang, Peng and Zhou, Xiaowei},
title = {Combined Truncated Sidelobe Suppression and Iterative Adaptive MAP Beamforming for Ultrasound Imaging},
journal = {IEEE Sensors Journal},
year = {2024},
volume = {24},
number = {24},
pages = {41563--41571},
doi = {10.1109/jsen.2024.3486735}
}
EUVIMED