EUVIMEDEUVIMED entdecken
Crossref

Microfluidic Microwave Sensor for Rapid Detection of Microplastics in Water: Optimization, Modeling, and Performance Evaluation

Haoxiang Wen, Yifan Zhao, Tingkai Shi, Mingxuan Li, Tao Li, Yiting Xu, Haiyang Jia, Wen Zhu, Longxiang Han, Sheng Yan, Jiawei Sun

IEEE Sensors Journal · 01.11.2024 · 24 (21) · 35599-35609

DOI: 10.1109/jsen.2024.3424270 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.11.2024. Verfasst von Haoxiang Wen und 10 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Science Foundation of Jiangsu Province, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, microplastics (MPs) have become the focal point of an increasing number of studies due to their potentially detrimental effects on human health. Currently, the detection of MPs poses an exceedingly challenging task, particularly methods that enable rapid, on-site detection. Herein, we have developed a rapid and microfluidic-based microwave detection sensor. By optimizing the parameters of the electric inductive-capacitive resonator and microfluidic channel, a noncontact sensor with a high sensitivity is successfully fabricated. This sensor concentrates the electromagnetic field between the coupling regions at a central frequency of 4.7 GHz, maximizing the interaction between the sample and the electric field. The results demonstrate that the microwave sensor exhibits high sensitivity by detecting the S11 resonance frequency shift of ~10 MHz with a 1% change in MP concentration. Notably, the as-fabricated sensor exhibits ideal linearity in various MP detections, and their coefficients of determination (CODs) reach astonishing levels of ~0.999, reflecting the excellent performance of the sensor. Simultaneously, the Maxwell-Garnett (MG) model has been applied for the first time to electromagnetic analysis in MP/water systems, confirming its high suitability for low-concentration scenarios. Based on this, a mathematical model has been established to provide a reasonable explanation for the excellent linearity. The high-performance sensors and theoretical analysis provide a new approach for future MP sensor design and fabrication, paving the way for on-site and rapid MP detection.

Förderung

  • National Science Foundation of Jiangsu Province
  • National Natural Science Foundation of China

Zitieren

APA

Wen, H., Zhao, Y., Shi, T., Li, M., Li, T., Xu, Y., Jia, H., Zhu, W., Han, L., Yan, S., & Sun, J. (2024). Microfluidic Microwave Sensor for Rapid Detection of Microplastics in Water: Optimization, Modeling, and Performance Evaluation. IEEE Sensors Journal, 24(21), 35599-35609. https://doi.org/10.1109/jsen.2024.3424270

Vancouver

Wen H, Zhao Y, Shi T, Li M, Li T, Xu Y, et al. Microfluidic Microwave Sensor for Rapid Detection of Microplastics in Water: Optimization, Modeling, and Performance Evaluation. IEEE Sensors Journal. 2024;24(21):35599-35609. doi:10.1109/jsen.2024.3424270

BibTeX
@article{Wen2024,
  author = {Wen, Haoxiang and Zhao, Yifan and Shi, Tingkai and Li, Mingxuan and Li, Tao and Xu, Yiting and Jia, Haiyang and Zhu, Wen and Han, Longxiang and Yan, Sheng and Sun, Jiawei},
  title = {Microfluidic Microwave Sensor for Rapid Detection of Microplastics in Water: Optimization, Modeling, and Performance Evaluation},
  journal = {IEEE Sensors Journal},
  year = {2024},
  volume = {24},
  number = {21},
  pages = {35599--35609},
  doi = {10.1109/jsen.2024.3424270}
}