Integrated NV (Nitrogen Vacancy) Vector Magnetometer in Real-Time Utilizing Frequency-Hopping Method
IEEE Sensors Journal · 01.05.2024 · 24 (9) · 14068-14075
DOI: 10.1109/jsen.2024.3374732 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.05.2024. Verfasst von Zhenhua Liu und 15 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Key Research and Development Program of China, NSFC Projects of International Cooperation and Exchanges, Shanxi Outstanding Youth Fund.
Abstract (Originalsprache)
Nitrogen vacancy (NV) centers in diamond exhibit the advantages of high resolution, high sensitivity, and error-free sensing in the field of vector field detection, which bolsters the potential of NV center magnetometers for practical applications. However, most of the NV center magnetometers are still limited by the constraints imposed by bulky laboratory instruments, and the method of sweeping frequency points to detect resonance frequencies can also lead to slower detection of vector magnetic fields (MF). To address these limitations and enhance the portability of integrated vector magnetometers, we made an integrated vector magnetometer based on NV centers and proposed a microwave (MW) frequency-hopping method to realize vector MF triaxial real-time (400 ms) detection. The experimental results indicate that the magnetometer dynamic range is $\pm 130 ~\mu \text{T}$ along the x-axis, $\pm 110 ~\mu \text{T}$ along the y-axis, and $\pm 260 ~\mu \text{T}$ along the z-axis, with the minimum standard deviation of vector MF measurements across all three axes being 1.84 nT. The frequency-hopping method is more than 87 times faster than the sweeping method and the size of the integrated NV magnetometer fits in the palm of the hand for portable usage. This proposal, which accomplishes vector MF rapidly measure using a self-made NV centers magnetometer, has potential applications in fields such as medical diagnosis, new energy battery testing, and geomagnetic detection.
Förderung
- National Key Research and Development Program of China
- NSFC Projects of International Cooperation and Exchanges
- Shanxi Outstanding Youth Fund
- Sci-Tech Cooperation and Exchange Project of Shanxi
- Key Laboratory of Quantum Sensing and Precision Measurement, Shanxi
Zitieren
APA
Liu, Z., Zheng, D., Fu, J., Tang, C., Liu, Y., Wang, H., Li, Y., Qin, L., Wen, H., Li, Z., Li, X., Guo, H., Tang, J., Li, Y., Ma, Z., & Liu, J. (2024). Integrated NV (Nitrogen Vacancy) Vector Magnetometer in Real-Time Utilizing Frequency-Hopping Method. IEEE Sensors Journal, 24(9), 14068-14075. https://doi.org/10.1109/jsen.2024.3374732
Vancouver
Liu Z, Zheng D, Fu J, Tang C, Liu Y, Wang H, et al. Integrated NV (Nitrogen Vacancy) Vector Magnetometer in Real-Time Utilizing Frequency-Hopping Method. IEEE Sensors Journal. 2024;24(9):14068-14075. doi:10.1109/jsen.2024.3374732
BibTeX
@article{Liu2024,
author = {Liu, Zhenhua and Zheng, Doudou and Fu, Jianghao and Tang, Chenchen and Liu, Yankang and Wang, Hui and Li, Yang and Qin, Li and Wen, Huanfei and Li, Zhonghao and Li, Xin and Guo, Hao and Tang, Jun and Li, Yan-Jun and Ma, Zongmin and Liu, Jun},
title = {Integrated NV (Nitrogen Vacancy) Vector Magnetometer in Real-Time Utilizing Frequency-Hopping Method},
journal = {IEEE Sensors Journal},
year = {2024},
volume = {24},
number = {9},
pages = {14068--14075},
doi = {10.1109/jsen.2024.3374732}
}