EUVIMEDEUVIMED entdecken
Crossref

High-Sensitivity Plantar Pressure Antenna Sensor Based on EBG Array for Gait Monitoring

Feng-Lu Hu, Dao-Lian Jiang, Xiu-Wei Xuan, Hong-Ji Li, Ming-Ji Li

IEEE Sensors Journal · 15.04.2024 · 24 (8) · 12322-12331

DOI: 10.1109/jsen.2024.3372947 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.04.2024. Verfasst von Feng-Lu Hu und 4 weiteren Autor:innen. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Nature Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prolonged use of electronic devices, especially with incorrect sitting and posture, may cause changes in spinal shape. These issues can affect the distribution of pressure on the soles of the feet. As postural diseases continue to rise in prevalence, wearable wireless plantar pressure monitoring is essential. This article proposed a wearable plantar pressure antenna sensor based on electromagnetic bandgap (EBG) array operating in the 2.45-GHz industrial, scientific, and medical (ISM) band. To measure the pressure, the antenna sensor adopts a dual-substrate structure whose gap is filled with foam. Applying pressure to the antenna will cause the gap to shrink, resulting in shifts of the antenna’s resonant frequency. By remotely reading the resonant frequency, wireless monitoring of plantar pressure can be achieved. The sensitivity of the antenna sensor to pressure is 1.06 MHz/N. In the two separate ${h}$ ranges of 4.5–3.25 mm and 3–1.5 mm, the $2\times2$ EBG array can increase the sensitivity of the antenna sensor by 35.4% and 39.3%, respectively. In addition, the EBG array can also reduce the specific absorption rate (SAR) of the antenna by approximately 95% and increase the gain from −0.8 to 6.6 dB. The simulated and measured results of the antenna sensor produced a good agreement.

Förderung

  • National Nature Science Foundation of China

Zitieren

APA

Hu, F., Jiang, D., Xuan, X., Li, H., & Li, M. (2024). High-Sensitivity Plantar Pressure Antenna Sensor Based on EBG Array for Gait Monitoring. IEEE Sensors Journal, 24(8), 12322-12331. https://doi.org/10.1109/jsen.2024.3372947

Vancouver

Hu F, Jiang D, Xuan X, Li H, Li M. High-Sensitivity Plantar Pressure Antenna Sensor Based on EBG Array for Gait Monitoring. IEEE Sensors Journal. 2024;24(8):12322-12331. doi:10.1109/jsen.2024.3372947

BibTeX
@article{Hu2024,
  author = {Hu, Feng-Lu and Jiang, Dao-Lian and Xuan, Xiu-Wei and Li, Hong-Ji and Li, Ming-Ji},
  title = {High-Sensitivity Plantar Pressure Antenna Sensor Based on EBG Array for Gait Monitoring},
  journal = {IEEE Sensors Journal},
  year = {2024},
  volume = {24},
  number = {8},
  pages = {12322--12331},
  doi = {10.1109/jsen.2024.3372947}
}
Kostenlos starten →