Live-Line Detection of Deteriorated Insulators on Overhead Transmission Lines Based on Electric Field Distribution
IEEE Sensors Journal · 15.01.2024 · 24 (2) · 1687-1695
DOI: 10.1109/jsen.2023.3332849 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.01.2024. Verfasst von Shaocheng Wu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Science and Technology Project of China Southern Power Grid Ltd, Liability Company.
Abstract (Originalsprache)
The presence of deteriorated insulators in power grids poses a significant threat to the safety of power transmission. The electric field detection method (EFDM) is considered an effective approach for detecting low or zero value insulators on high-voltage transmission lines. In this article, we analyzed the effects of the detection device, measurement angle, and insulator deterioration on the axial electric field value of insulator strings using both test values and simulation values. Our results indicated that the detection device had minimal impact on the normalized values of the axial electric field, whereas the measurement angle affected the values. However, the errors between the test values and the simulation values at the ends of the insulator strings were larger, indicating that the measurement device is better suited for measuring at nonends of the insulator strings. Based on our findings, we used the detection device to measure the electric field of insulator strings on a 220-kV transmission line. The results of the measurement showed that the electric field detector could accurately measure the axial electric field of the insulator string and detect deteriorated insulators, thereby providing a more effective measurement method. Our research thus confirms the feasibility of the EFDM in actual power transmission lines.
Förderung
- Science and Technology Project of China Southern Power Grid Ltd
- Liability Company
Zitieren
APA
Wu, S., Wang, L., Song, B., & Gao, J. (2024). Live-Line Detection of Deteriorated Insulators on Overhead Transmission Lines Based on Electric Field Distribution. IEEE Sensors Journal, 24(2), 1687-1695. https://doi.org/10.1109/jsen.2023.3332849
Vancouver
Wu S, Wang L, Song B, Gao J. Live-Line Detection of Deteriorated Insulators on Overhead Transmission Lines Based on Electric Field Distribution. IEEE Sensors Journal. 2024;24(2):1687-1695. doi:10.1109/jsen.2023.3332849
BibTeX
@article{Wu2024,
author = {Wu, Shaocheng and Wang, Linong and Song, Bin and Gao, Jiachen},
title = {Live-Line Detection of Deteriorated Insulators on Overhead Transmission Lines Based on Electric Field Distribution},
journal = {IEEE Sensors Journal},
year = {2024},
volume = {24},
number = {2},
pages = {1687--1695},
doi = {10.1109/jsen.2023.3332849}
}
EUVIMED