EUVIMEDEUVIMED entdecken
Crossref

An On-Line Full-Parameters Calibration Method for SINS/DVL Integrated Navigation System

Li Luo, Yulong Huang, Guoqing Wang, Yonggang Zhang, Lin Tang

IEEE Sensors Journal · 15.12.2023 · 23 (24) · 30927-30939

DOI: 10.1109/jsen.2023.3330874 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.12.2023. Verfasst von Li Luo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Sichuan Natural Science Youth Fund Project, Open Project of Guangxi Key Laboratory of Nuclear Physics and Nuclear Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this article, an on-line calibration method for strap-down inertial navigation system (SINS)/Doppler velocity log (DVL) based integrated navigation system is proposed to jointly estimate the calibration parameters of SINS and DVL, where the DVL lever arm and gyroscope scale factor error are considered. The full-parameters, including the gyroscope scale factor error, gyroscope bias, accelerometer bias, DVL installation misalignment angle, and DVL lever arm, are modeled as calibration parameters. A new state–space model for on-line calibration of SINS/DVL integrated navigation system is established, which also introduces the measurements of the global navigation satellite system (GNSS) and celestial navigation system (CNS) to improve the observability of calibration parameters. To suppress the effects of nonlinear error introduced by large installation error between SINS and DVL, a full-parameters feedback correction scheme is proposed. In addition, a special trajectory for the proposed on-line calibration method is designed based on the observability analysis results and the actual motion conditions of the ship, which ensures those calibration parameters in the calibration model can be observed. Simulation results and semi-physical simulation results illustrate that the proposed on-line calibration method can achieve better calibration results than existing methods compared in this article, and the full-parameters can be jointly calibrated online, even in the case of large installation errors between SINS and DVL.

Förderung

  • National Natural Science Foundation of China
  • Sichuan Natural Science Youth Fund Project
  • Open Project of Guangxi Key Laboratory of Nuclear Physics and Nuclear Technology
  • Central Government Guidance Funds for Local Scientific and Technological Development, China

Zitieren

APA

Luo, L., Huang, Y., Wang, G., Zhang, Y., & Tang, L. (2023). An On-Line Full-Parameters Calibration Method for SINS/DVL Integrated Navigation System. IEEE Sensors Journal, 23(24), 30927-30939. https://doi.org/10.1109/jsen.2023.3330874

Vancouver

Luo L, Huang Y, Wang G, Zhang Y, Tang L. An On-Line Full-Parameters Calibration Method for SINS/DVL Integrated Navigation System. IEEE Sensors Journal. 2023;23(24):30927-30939. doi:10.1109/jsen.2023.3330874

BibTeX
@article{Luo2023,
  author = {Luo, Li and Huang, Yulong and Wang, Guoqing and Zhang, Yonggang and Tang, Lin},
  title = {An On-Line Full-Parameters Calibration Method for SINS/DVL Integrated Navigation System},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {24},
  pages = {30927--30939},
  doi = {10.1109/jsen.2023.3330874}
}