EUVIMEDEUVIMED entdecken
Crossref

rGO-Based Memristive Sensor for Rapid Hydrogen Detection at Room Temperature

Nada AbuHamra, Heba Abunahla, Ashraf Ali, Waqas Waheed, Saleh T. Mahmoud, Anas Alazzam, Baker Mohammad

IEEE Sensors Journal · 15.12.2023 · 23 (24) · 30093-30101

DOI: 10.1109/jsen.2023.3328869 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 15.12.2023. Verfasst von Nada AbuHamra und 6 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: System-on-Chip Laboratory, Khalifa University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, there has been a growing interest in investigating the potential of emerging memristor (MR) devices for gas sensing applications, particularly at room temperature. This article reports on a planar Au/reduced graphene oxide (rGO)/Au memristive hydrogen sensor, fabricated on a cost-effective cyclic olefin copolymer (COC) substrate, and utilizing the rGO green carbon material as its active sensing element. The sensor’s performance is evaluated using two different testing modes: conventional chemiresistive testing under a constant voltage bias (CVB) and voltage pulse (VP) modes. The CVB mode demonstrates high repeatability, selectivity, response time, and recovery time, indicating the sensor’s reliable gas sensing capabilities. In addition, the VP mode significantly enhances the sensor’s relative percentage response, indicating its potential for improved gas sensing performance. To optimize the sensor’s response, the impact of hydrogen exposure on the MR resistive switching is studied, revealing that the effect is contingent on the VP amplitude. Specifically, gas-enhanced resistive switching is achieved at lower voltage levels, whereas at higher voltage levels, gas exposure slows down the rate of resistive switching. Consequently, voltage-pulse testing is conducted at two voltage magnitudes, low (2.5 V) and high (4.5 V), and the sensor’s response is enhanced from 0.5% under CVB mode to 786% under VP mode.

Förderung

  • System-on-Chip Laboratory, Khalifa University

Zitieren

APA

AbuHamra, N., Abunahla, H., Ali, A., Waheed, W., Mahmoud, S. T., Alazzam, A., & Mohammad, B. (2023). rGO-Based Memristive Sensor for Rapid Hydrogen Detection at Room Temperature. IEEE Sensors Journal, 23(24), 30093-30101. https://doi.org/10.1109/jsen.2023.3328869

Vancouver

AbuHamra N, Abunahla H, Ali A, Waheed W, Mahmoud ST, Alazzam A, et al. rGO-Based Memristive Sensor for Rapid Hydrogen Detection at Room Temperature. IEEE Sensors Journal. 2023;23(24):30093-30101. doi:10.1109/jsen.2023.3328869

BibTeX
@article{AbuHamra2023,
  author = {AbuHamra, Nada and Abunahla, Heba and Ali, Ashraf and Waheed, Waqas and Mahmoud, Saleh T. and Alazzam, Anas and Mohammad, Baker},
  title = {rGO-Based Memristive Sensor for Rapid Hydrogen Detection at Room Temperature},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {24},
  pages = {30093--30101},
  doi = {10.1109/jsen.2023.3328869}
}
Kostenlos starten →