Abstract (Originalsprache)

This article proposes a microwave sensor for breast phantom analysis and tumor detection. The sensor is developed on the small-size ( $25\times25$ mm2) low-cost RT/duroid 5880 substrate. The structure of the proposed sensor is made up of four sensory elements. The sensor performance is experimentally validated by the evaluation of the S-parameters and radiation patterns. The proposed sensor has a 2–30-GHz-wide operating bandwidth, lower mutual coupling ( ${S} _{{21}} \le -30$ dB) between the elements, and offered a desirable directional radiation pattern. Four types of breast phantoms are mimicked: normal phantom, phantom with 3-, 5-, and 10-mm tumor. Developed phantoms have experimented with the proposed sensor and tumor identification is carried out. Measurement of the S-parameters, i.e., reflection coefficients ( ${S} _{{11}}$ , ${S} _{{22}}$ , ${S} _{{33}}$ , ${S} _{{44}}$ ) and mutual coupling coefficient ( ${S} _{{21}}$ , ${S} _{{31}}$ , ${S} _{{41}}$ ) with and without tumor phantom is executed. A large difference in the peak value of the S-parameters results for normal and malignant phantoms is observed over the 2–20-GHz frequency range. Reflection results from data are further processed through principal component analysis (PCA) to better visualize the difference between normal and malignant phantoms. Obtained PCA results exhibited a significant difference between normal and malignant phantoms. Specific absorption rate (SAR) analysis is also performed to separate normal and malignant phantoms. The proposed approach is a noninvasive, low-cost modality and can analyze the phantoms for tumor detection.

Zitieren

APA

Sharma, M. K., Singh, S. P., Badola, P., Kumar, M., Saini, J. P., & Ekuakille, A. L. (2023). Noninvasive Microwave-Multielement Sensor for Breast Phantoms Analysis and Tumor Detection. IEEE Sensors Journal, 23(17), 20207-20214. https://doi.org/10.1109/jsen.2023.3296740

Vancouver

Sharma MK, Singh SP, Badola P, Kumar M, Saini JP, Ekuakille AL. Noninvasive Microwave-Multielement Sensor for Breast Phantoms Analysis and Tumor Detection. IEEE Sensors Journal. 2023;23(17):20207-20214. doi:10.1109/jsen.2023.3296740

BibTeX
@article{Sharma2023,
  author = {Sharma, Madan Kumar and Singh, Satya P. and Badola, Paarth and Kumar, Mithilesh and Saini, J. P. and Ekuakille, Aime’ Lay},
  title = {Noninvasive Microwave-Multielement Sensor for Breast Phantoms Analysis and Tumor Detection},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {17},
  pages = {20207--20214},
  doi = {10.1109/jsen.2023.3296740}
}
Kostenlos starten →