A Wearable Localized Surface Plasmons Antenna Sensor for Communication and Sweat Sensing

Chao Zhang, Pei Xiao, Zi-Tong Zhao, Zhu Liu, Jie Yu, Xin-Yu Hu, Hong-Bo Chu, Jian-Jiao Xu, Meng-Yao Liu, Qi Zou, Li Zhang, Qi Liu und 1 weitere

IEEE Sensors Journal · 01.06.2023 · 23 (11) · 11591-11599

DOI: 10.1109/jsen.2023.3266262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.06.2023. Verfasst von Chao Zhang und 12 weiteren Autor:innen. Die Arbeit wurde bisher 60-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Natural Science Foundation of Hunan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a novel wearable antenna sensor based on localized surface plasmons (LSPs) for communication and noninvasive sweat monitoring. The sensor is made up of corrugated plasmonic structures based on the conventional printed monopole antenna, which achieves multiband and miniaturization. The physical dimensions of the antenna sensor are $35\times34$ mm, with a thickness of only 0.13 mm. Simulated and measured results demonstrate that the proposed antenna sensor covers triple operating bands, including 2.4 and 5.8 GHz ISM bands, as well as high-frequency ultrawideband ranging from 7.89 to 9.56 GHz. The antenna sensor exhibits a good radiation pattern with a peak gain of 3.02 dBi and a high quality factor ( ${Q}$ ) up to 35. The use of polyimide as a dielectric substrate enables the antenna sensor to achieve flexibility and conformality, maintaining stable operating states even when bent and deformed. The specific absorption rate (SAR) values in three frequency bands are simulated and evaluated to ensure its safety for human health. Moreover, the resonant frequency of antenna sensor significantly shifts with the volume and concentration of sweat, indicating that the proposed sensor is highly sensitive to sweat volume and concentration with a sensitivity of 120 MHz/1 mm and 4.57 MHz/1 mm, respectively. The proposed wearable antenna sensor is a promising candidate for a sweat monitoring system for athletes or patients, allowing for health monitoring at any time and place.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Hunan Province

Zitieren

APA

Zhang, C., Xiao, P., Zhao, Z., Liu, Z., Yu, J., Hu, X., Chu, H., Xu, J., Liu, M., Zou, Q., Zhang, L., Liu, Q., & Li, G. (2023). A Wearable Localized Surface Plasmons Antenna Sensor for Communication and Sweat Sensing. IEEE Sensors Journal, 23(11), 11591-11599. https://doi.org/10.1109/jsen.2023.3266262

Vancouver

Zhang C, Xiao P, Zhao Z, Liu Z, Yu J, Hu X, et al. A Wearable Localized Surface Plasmons Antenna Sensor for Communication and Sweat Sensing. IEEE Sensors Journal. 2023;23(11):11591-11599. doi:10.1109/jsen.2023.3266262

BibTeX
@article{Zhang2023,
  author = {Zhang, Chao and Xiao, Pei and Zhao, Zi-Tong and Liu, Zhu and Yu, Jie and Hu, Xin-Yu and Chu, Hong-Bo and Xu, Jian-Jiao and Liu, Meng-Yao and Zou, Qi and Zhang, Li and Liu, Qi and Li, Gao-Sheng},
  title = {A Wearable Localized Surface Plasmons Antenna Sensor for Communication and Sweat Sensing},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {11},
  pages = {11591--11599},
  doi = {10.1109/jsen.2023.3266262}
}