EUVIMEDEUVIMED entdecken
Crossref

Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection

Yaopeng Cheng, Fupeng Wang, Jinghua Wu, Rui Liang, Qiang Wang, Yubin Wei, Jiachen Sun, Qian Li, Qingsheng Xue

IEEE Sensors Journal · 01.04.2023 · 23 (7) · 6757-6768

DOI: 10.1109/jsen.2023.3246508 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.04.2023. Verfasst von Yaopeng Cheng und 8 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Open Fund of State Key Laboratory of Applied Optics.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fixed wavelength modulation spectroscopy (FWMS) featured as that wavelength is modulated around a constant value instead of a dynamic scanning ramp in the standard wavelength modulation spectroscopy (WMS). To eliminate the influence of center wavelength drift on absorption measurement in the FWMS system, a software-based proportional–integral–derivative (PID) controller is developed to lock the laser wavelength at methane line 1653.72 nm for CH4 detection in this study. Moreover, two crucial parameters of PID, gain and integral time, are optimized to improve the laser wavelength locking performance. As a result, the laser wavelength is locked to the target CH4 line with a $1{\sigma }$ fluctuation less than 406 kHz (better than ${{{3.7} \times }}{{{10}}}^{{-{3}}}{\text {pm}}$ ) with a robust 100% locking success rate, which is the best result reported so far to our knowledge. Based on the wavelength locked FWMS CH4 sensor, linearity is tested to be ${R}^{{2}}$ = 0.998 in a low concentration range of 0–1000 ppm. The detection sensitivity is 52 ppb at 0.1 s and could be improved to 36 ppb if the integration time is extended to 1.4 s. Compared with standard WMS, CH4 detection stability is improved by five times.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Shandong Province
  • Open Fund of State Key Laboratory of Applied Optics
  • Fundamental Research Funds for the Central Universities
  • Shandong Postdoctoral Innovation Program, Key Research and Development Program of Shandong Province

Zitieren

APA

Cheng, Y., Wang, F., Wu, J., Liang, R., Wang, Q., Wei, Y., Sun, J., Li, Q., & Xue, Q. (2023). Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection. IEEE Sensors Journal, 23(7), 6757-6768. https://doi.org/10.1109/jsen.2023.3246508

Vancouver

Cheng Y, Wang F, Wu J, Liang R, Wang Q, Wei Y, et al. Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection. IEEE Sensors Journal. 2023;23(7):6757-6768. doi:10.1109/jsen.2023.3246508

BibTeX
@article{Cheng2023,
  author = {Cheng, Yaopeng and Wang, Fupeng and Wu, Jinghua and Liang, Rui and Wang, Qiang and Wei, Yubin and Sun, Jiachen and Li, Qian and Xue, Qingsheng},
  title = {Ultrastable Laser Wavelength Locking Technique Optimized for WMS-Based Methane Detection},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {7},
  pages = {6757--6768},
  doi = {10.1109/jsen.2023.3246508}
}
Kostenlos starten →