Self-Calibration Method of Sensors Array Errors Based on Rotation Measurement
IEEE Sensors Journal · 01.02.2023 · 23 (3) · 2311-2319
DOI: 10.1109/jsen.2022.3233638 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.02.2023. Verfasst von Ke Wang und 3 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hubei Province of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Array calibration is the premise of successful array signal processing. The active calibration needs to know the direction of arrival (DOA) of calibration source signals accurately; otherwise, the performance will deteriorate. Although the conventional self-calibration does not need accurate DOA of calibration sources, it may suffer from falling into the local extremum since there are too many parameters to be estimated. Thus, we propose a novel self-calibration method based on the rotation measurement. The rotation measurement is that the array receives signals from a fixed source with different array rotation angles. The proposed method jointly estimates array errors and DOAs of the sources by an alternative minimization (AM) algorithm. Through the derivation of a suitable initial value in the AM algorithm, we could improve the robustness and reduce the computational complexity. The proposed method can achieve as high calibration accuracy as the active method even if there is an error in the source DOA information and can apply to arbitrary planar arrays. Both simulation and field experiment results demonstrate the effectiveness of the proposed method.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Hubei Province of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Wang, K., Cheng, F., Yi, J., & Wan, X. (2023). Self-Calibration Method of Sensors Array Errors Based on Rotation Measurement. IEEE Sensors Journal, 23(3), 2311-2319. https://doi.org/10.1109/jsen.2022.3233638
Vancouver
Wang K, Cheng F, Yi J, Wan X. Self-Calibration Method of Sensors Array Errors Based on Rotation Measurement. IEEE Sensors Journal. 2023;23(3):2311-2319. doi:10.1109/jsen.2022.3233638
BibTeX
@article{Wang2023,
author = {Wang, Ke and Cheng, Feng and Yi, Jianxin and Wan, Xianrong},
title = {Self-Calibration Method of Sensors Array Errors Based on Rotation Measurement},
journal = {IEEE Sensors Journal},
year = {2023},
volume = {23},
number = {3},
pages = {2311--2319},
doi = {10.1109/jsen.2022.3233638}
}