EUVIMEDEUVIMED entdecken
Crossref

Self-Adjustable Galvanic Skin Response Sensor for Physiological Monitoring

Jose A. Miranda Calero, Alba Paez-Montoro, Celia Lopez-Ongil, Susana Paton

IEEE Sensors Journal · 01.02.2023 · 23 (3) · 3005-3019

DOI: 10.1109/jsen.2022.3233439 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.02.2023. Verfasst von Jose A. Miranda Calero und 3 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: Protección Integral de las víctimas de violencia de género mediante Computación Afectiva multimodal” (EMPATIACM) Project of Madrid Region Government through th….

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous physiological monitoring integrated within current wearable devices is a hot topic nowadays. Despite that, measuring physiological variables is still challenging due to intrinsic and extrinsic personal factors. This results in the need for smart, adjustable, and personalized sensing devices. Among the different physiological signals that can be measured, changes in skin conductance are extensively used in affective computing research. This measurement presents an unequivocal relationship with the sympathetic branch of the autonomous nervous system, which relates to emotional reactions. However, there is a lack of self-adjustable skin conductance sensors. This article presents a novel skin conductance analog front end to deal with individual physiological dynamics. We compared the performance of our system with other skin conductance sensor circuits presented in the literature. Moreover, the experimental results in this work come from the data collected in 47 women volunteers and are compared with the measurements with a reference physiological sensing system commonly used for validations. Finally, our system presents a competitive averaged sensitivity for a typical human electrodermal activity (EDA) range compared to the current state-of-the-art solutions. Experimental results show that the system achieves an averaged sensitivity of up to 0.33 nS for a range 0–40$\mu \text{S}$, with a relative error below 1% for fixed-resistance measurements and a 0.94 median correlation coefficient when directly comparing with the reference sensor. Moreover, we extracted and analyzed different physiological features in data from both sensors and obtained comparable results. Finally, this research is intended to boost the design and development of subject-independent and self-adjustable wearable sensors.

Förderung

  • Protección Integral de las víctimas de violencia de género mediante Computación Afectiva multimodal” (EMPATIACM) Project of Madrid Region Government through th…

Zitieren

APA

Calero, J. A. M., Paez-Montoro, A., Lopez-Ongil, C., & Paton, S. (2023). Self-Adjustable Galvanic Skin Response Sensor for Physiological Monitoring. IEEE Sensors Journal, 23(3), 3005-3019. https://doi.org/10.1109/jsen.2022.3233439

Vancouver

Calero JAM, Paez-Montoro A, Lopez-Ongil C, Paton S. Self-Adjustable Galvanic Skin Response Sensor for Physiological Monitoring. IEEE Sensors Journal. 2023;23(3):3005-3019. doi:10.1109/jsen.2022.3233439

BibTeX
@article{Calero2023,
  author = {Calero, Jose A. Miranda and Paez-Montoro, Alba and Lopez-Ongil, Celia and Paton, Susana},
  title = {Self-Adjustable Galvanic Skin Response Sensor for Physiological Monitoring},
  journal = {IEEE Sensors Journal},
  year = {2023},
  volume = {23},
  number = {3},
  pages = {3005--3019},
  doi = {10.1109/jsen.2022.3233439}
}
Kostenlos starten →