EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Next-Generation Multipollutant Air Quality Monitoring System

Saim Shahid, David J. Brown, Bryn Taylor, Mohammad Aljaidi, Phil Wright, Yue Cao, Omprakash Kaiwartya

IEEE Journal of Selected Areas in Sensors · 2026 · 3 · 291-307

DOI: 10.1109/jsas.2026.3707543 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Selected Areas in Sensors, 2026. Verfasst von Saim Shahid und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cobac Security Limited and Nottingham Trent University as a Match-Funded 3-year Ph.D. program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The U.K.’s Environment Act 2021 introduced a duty on the government to set at least two legally binding air-quality targets, focusing on fine particulate matter (PM $_{2.5}$ ). These targets aim for a 10 $\mu$ g/m $^{3}$ annual mean concentration and a 35% reduction in population exposure by 2040. In this context, this industry-funded research from Cobac Security Limited (U.K.) presents a next-generation multipollutant air quality monitoring (nGAQM) system focusing on data integrity and sovereignty, with energy-efficient and low-cost sensing. The nGAQM system measures air pollutants and particulate matter (PM $_{1.0}$ –PM $_{10}$ ), and couples them with temperature, relative humidity, and Global Navigation Satellite System metadata to produce time and geo-tagged data records. A decoupled dual-microcontroller architecture assigns deterministic, nonblocking acquisition and lightweight edge processing to an ultra-low-power STM32U083RC, while an ESP32-C3 coprocessor handles networking and MQTT telemetry to a self-hosted ThingsBoard server. Measurements are logged locally to a microSD “data lake” in parallel with cloud telemetry for fault-tolerant retention. In-field system evaluation at a default 3-s schedule includes: first, an indoor high-transient cooking scenario, second, 24 h static outdoor deployments contrasting an urban street-canyon site with a rural background site, and third, a mobile city-center walk. The performance evaluation results show contextually interpretable multipollutant dynamics (traffic-coupled peaks, distinct outdoor baselines, and indoor transients), reliable operation with stable telemetry timing (96.87% of interarrival intervals were $\leq$ 3 s) and zero end-to-end loss ratio over the evaluated window. The nGAQM system provides an extensible, AI-ready foundation for future data-driven calibration and privacy-preserving system analytics.

Förderung

  • Cobac Security Limited and Nottingham Trent University as a Match-Funded 3-year Ph.D. program

Zitieren

APA

Shahid, S., Brown, D. J., Taylor, B., Aljaidi, M., Wright, P., Cao, Y., & Kaiwartya, O. (2026). Next-Generation Multipollutant Air Quality Monitoring System. IEEE Journal of Selected Areas in Sensors, 3, 291-307. https://doi.org/10.1109/jsas.2026.3707543

Vancouver

Shahid S, Brown DJ, Taylor B, Aljaidi M, Wright P, Cao Y, et al. Next-Generation Multipollutant Air Quality Monitoring System. IEEE Journal of Selected Areas in Sensors. 2026;3:291-307. doi:10.1109/jsas.2026.3707543

BibTeX
@article{Shahid2026,
  author = {Shahid, Saim and Brown, David J. and Taylor, Bryn and Aljaidi, Mohammad and Wright, Phil and Cao, Yue and Kaiwartya, Omprakash},
  title = {Next-Generation Multipollutant Air Quality Monitoring System},
  journal = {IEEE Journal of Selected Areas in Sensors},
  year = {2026},
  volume = {3},
  pages = {291--307},
  doi = {10.1109/jsas.2026.3707543}
}
Kostenlos starten →