EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A 24-GHz Frequency-Locked Loop-Based Microwave Microfluidic Sensor for Concentration Detection

Hsiu-Che Chang, Chung-Tse Michael Wu, Chao-Hsiung Tseng

IEEE Journal of Selected Areas in Sensors · 2024

DOI: 10.1109/jsas.2024.3395424 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Selected Areas in Sensors, 2024. Verfasst von Hsiu-Che Chang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents a 24-GHz microfluidic sensor using frequency-locked loop (FLL) technology for detecting liquid concentrations. The sensor, based on FLL, features a microfluidic channel placed over an asymmetrical coplanar waveguide resonator (ACPWR) that functions as a sensing device. For testing purposes, we use ethanol–water mixtures and glucose–water solutions as the liquid under test. Due to the electric field distribution in media with varying dielectric constants, the phase of the signal undergoes different phase deviations. The FLL-based sensor is capable of detecting these phase deviations and, in response, produces a frequency-modulated signal. This signal is subsequently demodulated into a corresponding voltage with the aid of a frequency demodulator, realized through a phase detector. Consequently, the sensor demonstrates the capability to differentiate between tested liquids of varying concentrations and offers a linear response that correlates the output voltage with the liquid concentration. The proposed 24-GHz FLL microfluidic sensor offers advantages, such as cost effective, high sensitivity, and compact size. It has a great possibility to implement this sensor using the system-on-chip technology. As it combined with Internet of Things technologies, it may have a capability of real-time biomedical specimen sensing for daily life.

Förderung

  • Ministry of Education

Zitieren

APA

Chang, H., Wu, C. M., & Tseng, C. (2024). A 24-GHz Frequency-Locked Loop-Based Microwave Microfluidic Sensor for Concentration Detection. IEEE Journal of Selected Areas in Sensors. https://doi.org/10.1109/jsas.2024.3395424

Vancouver

Chang H, Wu CM, Tseng C. A 24-GHz Frequency-Locked Loop-Based Microwave Microfluidic Sensor for Concentration Detection. IEEE Journal of Selected Areas in Sensors. 2024. doi:10.1109/jsas.2024.3395424

BibTeX
@article{Chang2024,
  author = {Chang, Hsiu-Che and Wu, Chung-Tse Michael and Tseng, Chao-Hsiung},
  title = {A 24-GHz Frequency-Locked Loop-Based Microwave Microfluidic Sensor for Concentration Detection},
  journal = {IEEE Journal of Selected Areas in Sensors},
  year = {2024},
  doi = {10.1109/jsas.2024.3395424}
}