Highly-Sensitive Thermally-Stabilized Palladium Cantilever Nanogap H 2 Sensor
Journal of Microelectromechanical Systems · 2026-04 · 35 (2) · 347-357
DOI: 10.1109/jmems.2026.3667443 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Microelectromechanical Systems, 2026-04. Verfasst von Amirali Nikeghbal und 7 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Gefördert von: U.S. Department of Energy (DOE) Advanced Research Projects Agency-Energy, SEAfloor Self-Sustaining CO2 Assessment Probe Edge.
Abstract (Originalsprache)
We present a new palladium-based nanogap hydrogen sensor designed for fast, low-concentration H 2 detection in environmental monitoring applications. The device consists of a long electrically-conductive low-stress palladium cantilever beam separated by a nanometer-sized air gap from a second cantilever beam of different length placed near the first beam tip thus forming a H 2 -dependent capacitor. The cantilevers are anchored on top of a thermally-isolated SiN membrane with an integrated microheater that maintains the sensor at constant temperature. When exposed to H 2 , the capacitor nanogap is reduced resulting in a change in capacitance with H 2 sensitivity $S_{\mathrm {H2}} =0.15$ fF/ppm. The sensor shows a consistent response up to $55~^{\circ }$ C with a thermal drift smaller than 0.22 aF/ o C and a minimum detectable signal of 10 ppm. The device repeatability was confirmed across 5 consecutive test cycles. Selectivity tests show negligible response to common interfering gases CO, CO 2 , CH 4 , water vapor and NH 3 ( $S_{i}\lt 5.2\times 1{0}^{-6}$ fF/ppm). The sensor exhibited a response time of approximately 390 ms upon exposure to H 2 .[2025-0141]
Förderung
- U.S. Department of Energy (DOE) Advanced Research Projects Agency-Energy
- SEAfloor Self-Sustaining CO2 Assessment Probe Edge
Zitieren
APA
Nikeghbal, A., Hasan, M. R., Sium, F. S., Momeni, F., Deshpande, A., Noh, S., Kim, H., & Mastrangelo, C. H. (2026). Highly-Sensitive Thermally-Stabilized Palladium Cantilever Nanogap H 2 Sensor. Journal of Microelectromechanical Systems, 35(2), 347-357. https://doi.org/10.1109/jmems.2026.3667443
Vancouver
Nikeghbal A, Hasan MR, Sium FS, Momeni F, Deshpande A, Noh S, et al. Highly-Sensitive Thermally-Stabilized Palladium Cantilever Nanogap H 2 Sensor. Journal of Microelectromechanical Systems. 2026;35(2):347-357. doi:10.1109/jmems.2026.3667443
BibTeX
@article{Nikeghbal2026,
author = {Nikeghbal, Amirali and Hasan, Md. Rabiul and Sium, Farhan Sadik and Momeni, Fatemeh and Deshpande, Adwait and Noh, Seungbeom and Kim, Hanseup and Mastrangelo, Carlos H.},
title = {Highly-Sensitive Thermally-Stabilized Palladium Cantilever Nanogap H 2 Sensor},
journal = {Journal of Microelectromechanical Systems},
year = {2026},
volume = {35},
number = {2},
pages = {347--357},
doi = {10.1109/jmems.2026.3667443}
}
EUVIMED