Receiver-Tilt-Robust RSS-Based VLP System Using a Normal Orthogonal Three-PD (NO3PD) Positioning Scheme
Journal of Lightwave Technology · 2026-08 · 44 (15) · 6636-6643
DOI: 10.1109/jlt.2026.3703051 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Lightwave Technology, 2026-08. Verfasst von Zhengliang Wang und 3 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
In received signal strength (RSS)-based visible light positioning (VLP) systems, receiver tilt directly affects the measured RSS and introduces bias into positioning estimates. To mitigate this issue, a normal orthogonal three-PD (NO3PD) structure is proposed to receive the positioning signal, where three PDs are arranged with mutually perpendicular normals. Theoretically, using the root-mean-square (RMS) of the RSS values from the NO3PD receiver for positioning eliminates the influence of tilt. To further reduce the complexity of the RSS extraction method, a cross-correlation-computed RSS (cccRSS) extraction method is proposed. To validate the robustness of the proposed NO3PD-based scheme against receiver tilt, we compare it with a single-PD-based scheme through simulations and experiments. Simulation results show that in a $\text{100}\,\text{cm} \times \text{100}\,\text{cm} \times \text{160}\,\text{cm}$ space with the receiver tilt angle ranging from $0^{\circ }$ to $15^{\circ }$ , the NO3PD-based scheme achieves a maximum average positioning error of 2.91 cm with a range of 0.39 cm, while the single-PD-based scheme achieves 4.17 cm and 1.78 cm, respectively. Experimental results in a similarly sized space, with the receiver tilt angle ranging from $0^{\circ }$ to $13.1^{\circ }$ , show that the NO3PD-based scheme attains a maximum average positioning error of 4.67 cm and a range of 0.98 cm, compared to 6.78 cm and 3.37 cm for the single-PD scheme. To assess the time performance of cccRSS extraction method, we implement the method on a microcontroller unit (MCU) and compare it with a fast Fourier transform (FFT)-based method, showing that it consumes only 6.4% of the computation time of the latter. Furthermore, at a receiver speed of 35 cm/s without tilt, real-time positioning using the NO3PD-based scheme achieves an average positioning error of 3.93 cm, which is consistent with the previous error. Overall, the proposed NO3PD-based scheme exhibits smaller error ranges under tilt variation and achieves centimeter-level real-time positioning, demonstrating its superior tilt robustness and real-time capability.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wang, Z., Xu, H., Yang, A., & Qiao, Y. (2026). Receiver-Tilt-Robust RSS-Based VLP System Using a Normal Orthogonal Three-PD (NO3PD) Positioning Scheme. Journal of Lightwave Technology, 44(15), 6636-6643. https://doi.org/10.1109/jlt.2026.3703051
Vancouver
Wang Z, Xu H, Yang A, Qiao Y. Receiver-Tilt-Robust RSS-Based VLP System Using a Normal Orthogonal Three-PD (NO3PD) Positioning Scheme. Journal of Lightwave Technology. 2026;44(15):6636-6643. doi:10.1109/jlt.2026.3703051
BibTeX
@article{Wang2026,
author = {Wang, Zhengliang and Xu, Hang and Yang, Aiying and Qiao, Yaojun},
title = {Receiver-Tilt-Robust RSS-Based VLP System Using a Normal Orthogonal Three-PD (NO3PD) Positioning Scheme},
journal = {Journal of Lightwave Technology},
year = {2026},
volume = {44},
number = {15},
pages = {6636--6643},
doi = {10.1109/jlt.2026.3703051}
}
EUVIMED