EUVIMEDEUVIMED entdecken
Crossref

Flow-Induced Vibration-Based Liquid Flow Rate Measurement With Optical Carrier Microwave Interferometry

Songlin Li, Ting Xue, Yan Wu, Bin Wu

Journal of Lightwave Technology · 01.07.2026 · 44 (13) · 5782-5789

DOI: 10.1109/jlt.2026.3690942 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Lightwave Technology, erschienen am 01.07.2026. Verfasst von Songlin Li und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate liquid flow rate measurement is essential for efficient energy management and sustainable development. In this paper, a novel non-intrusive liquid flow rate measurement method based on optical carrier microwave interferometry (OCMI) combined with flow-induced vibration (FIV) is developed. The theoretical principle of FIV is presented, and the liquid flow rate mathematical model based on FIV is established. In the experiment, the sensing fiber is helically wrapped around the outer surface of the pipeline to effectively capture FIV signals. The Fabry-Perot interferometers (FPIs) are categorized into two types: sensing FPIs incorporating the helical fiber and reference FPIs without it. Experimental results demonstrate that sensing FPIs exhibit a strong response to liquid flow rate variations through pipeline vibrations, with a pronounced quadratic relationship between the dip frequency and the flow rate. The fitted curve achieves high accuracy, yielding a mean absolute error and root mean square error of less than 4 kHz and 5 kHz, respectively. The comparative analysis between sensing and reference FPIs not only corroborates the validity of the derived theoretical model but also confirms the effectiveness and reliability of the proposed approach, which presents a promising, non-intrusive solution for liquid flow rate monitoring in practical industrial applications.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, S., Xue, T., Wu, Y., & Wu, B. (2026). Flow-Induced Vibration-Based Liquid Flow Rate Measurement With Optical Carrier Microwave Interferometry. Journal of Lightwave Technology, 44(13), 5782-5789. https://doi.org/10.1109/jlt.2026.3690942

Vancouver

Li S, Xue T, Wu Y, Wu B. Flow-Induced Vibration-Based Liquid Flow Rate Measurement With Optical Carrier Microwave Interferometry. Journal of Lightwave Technology. 2026;44(13):5782-5789. doi:10.1109/jlt.2026.3690942

BibTeX
@article{Li2026,
  author = {Li, Songlin and Xue, Ting and Wu, Yan and Wu, Bin},
  title = {Flow-Induced Vibration-Based Liquid Flow Rate Measurement With Optical Carrier Microwave Interferometry},
  journal = {Journal of Lightwave Technology},
  year = {2026},
  volume = {44},
  number = {13},
  pages = {5782--5789},
  doi = {10.1109/jlt.2026.3690942}
}
Kostenlos starten →