EUVIMEDEUVIMED entdecken
Crossref

High-Resolution Strain Demodulation via Spectrogram Reassignment-Assisted OFDR for Esophageal Manometry

Zihang Ji, Lei Tu, Tianle Chen, Zhou Xu, Liang Wang, Ming Tang

Journal of Lightwave Technology · 15.06.2026 · 44 (12) · 5241-5248

DOI: 10.1109/jlt.2026.3686098 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Lightwave Technology, erschienen am 15.06.2026. Verfasst von Zihang Ji und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Interdisciplinary Research Program of HUST, National Key R&D Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-resolution manometry (HRM), as a critical diagnostic method for gastrointestinal diseases, is widely employed for esophageal manometry. However, existing water-perfused catheters and expensive solid-state catheters to realize HRM suffer from either limited frequency response or insufficient spatial resolution. On the other hand, fiber-optic manometry sensor based on optical frequency domain reflectometry (OFDR) can realize distributed measurement at high spatial resolution. Nevertheless, there is a tradeoff between strain resolution and sensing resolution in conventional OFDR, which prevents it from achieving both high sensing resolution and pressure resolution in esophageal manometry, making it difficult to satisfy the HRM requirement. To address this, we propose a spectrogram reassignment (SR) method for strain demodulation, which simultaneously enhances the sensing resolution and strain resolution in OFDR but without much deterioration of the demodulation speed. The experiment results demonstrate a sensing resolution of 1.4 mm and strain resolution of 1.9 μϵ, showing over 4 times improvement when compared with the conventional OFDR. Using the fabricated fiber-optic manometry sensor with 80 μm diameter bend-insensitive fiber, our SR-assisted OFDR demonstrates a pressure sensitivity of 1.97 μϵ/mmHg and pressure resolution of 0.96 mmHg within traditional esophageal pressure range of 0∼300 mmHg, satisfying the HRM requirement. This is the first work to present an OFDR fiber-optic manometry sensor that meets the HRM requirement, and it provides a competitive method for esophageal manometry.

Förderung

  • National Natural Science Foundation of China
  • Interdisciplinary Research Program of HUST
  • National Key R&D Program of China
  • Key R&D Program of Hubei Province
  • Natural Science Foundation of Wuhan
  • Wuhan Union Hospital Medical-Engineering Interdisciplinary Research Support Program

Zitieren

APA

Ji, Z., Tu, L., Chen, T., Xu, Z., Wang, L., & Tang, M. (2026). High-Resolution Strain Demodulation via Spectrogram Reassignment-Assisted OFDR for Esophageal Manometry. Journal of Lightwave Technology, 44(12), 5241-5248. https://doi.org/10.1109/jlt.2026.3686098

Vancouver

Ji Z, Tu L, Chen T, Xu Z, Wang L, Tang M. High-Resolution Strain Demodulation via Spectrogram Reassignment-Assisted OFDR for Esophageal Manometry. Journal of Lightwave Technology. 2026;44(12):5241-5248. doi:10.1109/jlt.2026.3686098

BibTeX
@article{Ji2026,
  author = {Ji, Zihang and Tu, Lei and Chen, Tianle and Xu, Zhou and Wang, Liang and Tang, Ming},
  title = {High-Resolution Strain Demodulation via Spectrogram Reassignment-Assisted OFDR for Esophageal Manometry},
  journal = {Journal of Lightwave Technology},
  year = {2026},
  volume = {44},
  number = {12},
  pages = {5241--5248},
  doi = {10.1109/jlt.2026.3686098}
}
Kostenlos starten →