EUVIMEDEUVIMED entdecken
Crossref

Microbubble Resonators for Photoacoustic Detection and Photothermal Spectroscopy

Gabriele Frigenti, Lucia Cavigli, Fulvio Ratto, Sonia Centi, Tupak García-Fernández, Daniele Farnesi, Stefano Pelli, Silvia Soria, Gualtiero Nunzi Conti

Journal of Lightwave Technology · 01.07.2023 · 41 (13) · 4137-4144

DOI: 10.1109/jlt.2023.3240698 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Lightwave Technology, erschienen am 01.07.2023. Verfasst von Gabriele Frigenti und 8 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical microresonators based on Whispering Gallery Modes have been extensively investigated as unique tools for fundamental studies and as core components in several applications. Specifically, microbubbles resonators (MBR) made from glass capillaries combine high optical and mechanical Q-factors together with intrinsic microfluidics, and in this work we demonstrate them as unique platforms for photoacoustic (PA) detection and photothermal (PT) spectroscopy. In a first configuration, we employed a MBR as an optical transducer to detect the PA signal generated by a suspension of gold nanorods (GNRs) placed within the MBR, demonstrating all-optical PA detection and high sensitivity towards nanoparticles optical absorption. The MBR acts both as the ultrasound sensor and as the microvial, enabling the inspection of submicroliter samples without the need for impedance-matching media. We then present a flow cytometry experiment where the GNRs run through the MBR, and we estimate PA intensity by a Fourier analysis of the read-out signal. The sharp MBR mechanical eigenmodes allowed to easily decouple the environmental noise from the PA contributions. In a second proof-of-concept experiment using a similar setup, we implemented the MBR transducer to reconstruct the GNRs absorption spectrum through the photothermal conversion. The high sensitivity of the MBR towards temperature variations allowed for the interrogation of small samples while using a low-intensity beam for their excitation. This thermal detection produces spectra that are insensitive towards light scattering in the sample, as proved experimentally by comparing the spectra of aqueous GNR suspensions in the presence or absence of milk powder.

Zitieren

APA

Frigenti, G., Cavigli, L., Ratto, F., Centi, S., García-Fernández, T., Farnesi, D., Pelli, S., Soria, S., & Conti, G. N. (2023). Microbubble Resonators for Photoacoustic Detection and Photothermal Spectroscopy. Journal of Lightwave Technology, 41(13), 4137-4144. https://doi.org/10.1109/jlt.2023.3240698

Vancouver

Frigenti G, Cavigli L, Ratto F, Centi S, García-Fernández T, Farnesi D, et al. Microbubble Resonators for Photoacoustic Detection and Photothermal Spectroscopy. Journal of Lightwave Technology. 2023;41(13):4137-4144. doi:10.1109/jlt.2023.3240698

BibTeX
@article{Frigenti2023,
  author = {Frigenti, Gabriele and Cavigli, Lucia and Ratto, Fulvio and Centi, Sonia and García-Fernández, Tupak and Farnesi, Daniele and Pelli, Stefano and Soria, Silvia and Conti, Gualtiero Nunzi},
  title = {Microbubble Resonators for Photoacoustic Detection and Photothermal Spectroscopy},
  journal = {Journal of Lightwave Technology},
  year = {2023},
  volume = {41},
  number = {13},
  pages = {4137--4144},
  doi = {10.1109/jlt.2023.3240698}
}
Kostenlos starten →