Prognosis for Filament Degradation of X-Ray Tubes Based on IoMT Time Series Data
IEEE Internet of Things Journal · 01.04.2025 · 12 (7) · 8084-8094
DOI: 10.1109/jiot.2024.3501298 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Internet of Things Journal, erschienen am 01.04.2025. Verfasst von Jie Zhong und 4 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Key Research and Development Program of China.
Abstract (Originalsprache)
The X-ray tube is the core component of computed tomography (CT) equipment, directly affecting imaging resolution and diagnostic accuracy. Degradation and failure prediction ensures the safe and reliable operation of X-ray tube. This article proposes a filament degradation prediction method for X-ray tubes based on Internet of Medical Things (IoMT) time-series data. First, this article analyzes the degradation mechanism of the filament and construct a health indicator based on filament current. Subsequently, key setting parameters are fixed to filter the original data, obtaining pure degradation information. Then, a multiscale attention prediction (MSAP) model is constructed to learn the filament degradation process from historical filament current data, and an ensemble epistemic uncertainty capture method is proposed to ascertain the uncertainty of prediction results. Finally, a failure threshold determining method is designed to predict the remaining useful life of the tube. Supported by the IoMT platform of West China Hospital, clinical monitoring data from four X-ray tubes that failed due to filament burnout were collected. Experimental results demonstrate that the proposed method outperforms existing state-of-the-art methods, achieving root mean square error and score values of 0.0249 and 0.0016, respectively. The proposed maintenance strategy is anticipated to yield economic benefits of 126 000–31 500 yuan per X-ray tube, significantly reducing downtime, and ensuring timely treatment for patients.
Förderung
- National Key Research and Development Program of China
Zitieren
APA
Zhong, J., Zhang, H., Liu, Q., Miao, Q., & Huang, J. (2025). Prognosis for Filament Degradation of X-Ray Tubes Based on IoMT Time Series Data. IEEE Internet of Things Journal, 12(7), 8084-8094. https://doi.org/10.1109/jiot.2024.3501298
Vancouver
Zhong J, Zhang H, Liu Q, Miao Q, Huang J. Prognosis for Filament Degradation of X-Ray Tubes Based on IoMT Time Series Data. IEEE Internet of Things Journal. 2025;12(7):8084-8094. doi:10.1109/jiot.2024.3501298
BibTeX
@article{Zhong2025,
author = {Zhong, Jie and Zhang, Heng and Liu, Qilin and Miao, Qiang and Huang, Jin},
title = {Prognosis for Filament Degradation of X-Ray Tubes Based on IoMT Time Series Data},
journal = {IEEE Internet of Things Journal},
year = {2025},
volume = {12},
number = {7},
pages = {8084--8094},
doi = {10.1109/jiot.2024.3501298}
}