EUVIMEDEUVIMED entdecken
Crossref

Microwave Stripline Probe for Pharmaceutical Hydrogel Swelling Detection

Shabbir Chowdhury, Amir Ebrahimi, Nazim Nassar, Kamran Ghorbani, Francisco Tovar-Lopez

IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · 2026-03 · 10 (1) · 88-98

DOI: 10.1109/jerm.2025.3628322 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 2026-03. Verfasst von Shabbir Chowdhury und 4 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: CASS Foundation Medicine/Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article presents an approach for real-time, non-invasive monitoring of hydrogel swelling dynamics using a microwave probe sensor. A compact stripline probe has been designed to detect dielectric variations caused by water uptake in the pharmaceutical hydrogel APO-Metformin XR 1000. Swelling induces changes in effective permittivity, resulting in a measurable downward shift in the resonance frequency, observed through the input reflection coefficient ($S_{11}$). These frequency shifts can then be processed and used to detect the swelling ratio. The operation principle of the probe, its sensitivity, and the design procedure are explained using an accurate circuit model analysis. A prototype of the probe has been fabricated, and experimental measurements using a pharmaceutical hydrogel were conducted to verify the proposed sensing principle. Controlled experiments under consistent mechanical pressure and hydration conditions demonstrated a correlation between hydrogel swelling ratio and resonance frequency shift, with an exponential decay fit (R$^{2}$ = 0.994). Repeatability tests confirmed high measurement stability, with average sensitivity of 90 MHz/g of water absorption. The results highlight the potential of microwave sensing as a sensitive, label-free, and scalable platform for characterizing hydrogel hydration, enabling new opportunities in biomedical diagnostics, drug delivery systems, smart materials, and real-time drug-release monitoring.

Förderung

  • CASS Foundation Medicine/Science

Zitieren

APA

Chowdhury, S., Ebrahimi, A., Nassar, N., Ghorbani, K., & Tovar-Lopez, F. (2026). Microwave Stripline Probe for Pharmaceutical Hydrogel Swelling Detection. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 10(1), 88-98. https://doi.org/10.1109/jerm.2025.3628322

Vancouver

Chowdhury S, Ebrahimi A, Nassar N, Ghorbani K, Tovar-Lopez F. Microwave Stripline Probe for Pharmaceutical Hydrogel Swelling Detection. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology. 2026;10(1):88-98. doi:10.1109/jerm.2025.3628322

BibTeX
@article{Chowdhury2026,
  author = {Chowdhury, Shabbir and Ebrahimi, Amir and Nassar, Nazim and Ghorbani, Kamran and Tovar-Lopez, Francisco},
  title = {Microwave Stripline Probe for Pharmaceutical Hydrogel Swelling Detection},
  journal = {IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology},
  year = {2026},
  volume = {10},
  number = {1},
  pages = {88--98},
  doi = {10.1109/jerm.2025.3628322}
}