An Auxetic Loop-Resonator Based on Hexagonal Re-Entrant Structure for Enhanced Microwave Strain Sensing
IEEE Access · 2026 · 14 · 164811-164822
DOI: 10.1109/access.2026.3746680 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von A. P. Praveen und 3 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Amrita Vishwa Vidyapeetham through the Article Processing Charge, Council of Scientific and Industrial Research (CSIR), Government of India, through the Senior Research Fellowship.
Abstract (Originalsprache)
The prominence of microwave sensors in structural health monitoring (SHM) and healthcare devices arises from their adaptability, superior sensitivity, and wireless communication capabilities. Even subtle discrepancies within the system can be efficiently captured through the electric field fluctuations, making them superior to other sensing techniques. This paper investigates the strain-sensing capability of a microwave resonator sensor and its structural modifications for sensitivity enhancement. A traditional square-shaped open-loop resonator (SOLR) is designed as a band-stop filter and is modified to a hexagonal re-entrant auxetic structure. This newly proposed resonator is referred to as an auxetic open-loop resonator (AOLR), and the structure selection depends on its unique deformation behaviour, presuming that the effects of additional corners and surface current paths will benefit sensitivity enhancement. Subsequently, the SOLR design is modified into the AOLR through multiple finite element (FE) simulations while ensuring the auxetic nature of the structure. The design therefore involves a trade-off between selecting the re-entrant geometric parameters required for auxetic behaviour and maintaining the desired resonant frequency and filter characteristics within the same external footprint. Tensile test experiments are performed to determine the response of both sensors, and a high sensitivity of - $14.1~\pm ~3$ kHz/ $\mu \varepsilon $ is obtained for the AOLR, which is almost double that of the SOLR. The results indicate that the negative Poisson’s ratio (NPR)-driven re-entrant auxetic structure is ideal for sub-millimetre range ( $\leq 500\mu \varepsilon $ ) strain measurements. In addition to the auxetic amplification effects, a strong confinement of electromagnetic energy and additional capacitance due to the structural slot make the AOLR a strong candidate for this application. The findings of the current research are directly linked to the sustainable development goals (SDGs) established by the United Nations (UN), specifically objective 9, which focuses on resilient and smart infrastructure.
Förderung
- Amrita Vishwa Vidyapeetham through the Article Processing Charge
- Council of Scientific and Industrial Research (CSIR), Government of India, through the Senior Research Fellowship
Zitieren
APA
Praveen, A. P., Menon, S. K., Donelli, M., & Hariprasad, M. P. (2026). An Auxetic Loop-Resonator Based on Hexagonal Re-Entrant Structure for Enhanced Microwave Strain Sensing. IEEE Access, 14, 164811-164822. https://doi.org/10.1109/access.2026.3746680
Vancouver
Praveen AP, Menon SK, Donelli M, Hariprasad MP. An Auxetic Loop-Resonator Based on Hexagonal Re-Entrant Structure for Enhanced Microwave Strain Sensing. IEEE Access. 2026;14:164811-164822. doi:10.1109/access.2026.3746680
BibTeX
@article{Praveen2026,
author = {Praveen, A. P. and Menon, Sreedevi K. and Donelli, Massimo and Hariprasad, M. P.},
title = {An Auxetic Loop-Resonator Based on Hexagonal Re-Entrant Structure for Enhanced Microwave Strain Sensing},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {164811--164822},
doi = {10.1109/access.2026.3746680}
}
EUVIMED