Direct Maximum Power Point Identification Based on Explicit I – V Curve Approximation for Photovoltaic Modules in DC Microgrids
IEEE Access · 2026 · 14 · 169724-169739
DOI: 10.1109/access.2026.3746515 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Shahrazed Elmetennani und 1 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research, Development, and Innovation Authority (RDIA), Saudi Arabia.
Abstract (Originalsprache)
Operating at the Maximum Power Point (MPP) is essential for photovoltaic (PV) arrays in a wide scope of applications, from small-scale rooftops to grid-scale plants. However, accurate identification remains challenging because the MPP shifts continuously due to intermittent changes in irradiance and temperature. To address this challenge, this paper presents a model-based, non-iterative algorithm for direct analytical MPP identification. First, the five parameters of the single-diode model (SDM) are estimated online by solving a sequence of linear least-squares problems using a set of PV current and voltage (I, V) measurements. Second, the resulting parameters are used to fit the power region of the PV current-voltage (I-V) curve with a third-order polynomial, which can be manipulated analytically to identify the MPP operating point via Cardano’s formula, without iterative search. This algorithm can be implemented online with the PV module connected to a stiff microgrid DC bus and reliably runs on an embedded microcontroller under these constrained conditions. Numerical validation across six PV technologies shows that the proposed method achieves higher MPP accuracy, on average, than state-of-the-art model-based non-iterative MPP identification techniques. Furthermore, compared to an iterative Newton-Raphson solver on an ARM Cortex-M3 microcontroller, whose execution speed and convergence depend critically on a well-selected initial guess, the proposed algorithm exhibited favorable estimation accuracy and predictable execution time independent of initialization. The algorithm was further validated experimentally on a PV module connected to a DC microgrid, completing data collection, parameter estimation, and MPP calculation online in under one second across different operating conditions. These results position the proposed method as a practical, accurate, initialization-free, and computationally efficient solution for real-time MPP identification in embedded PV systems.
Förderung
- Research, Development, and Innovation Authority (RDIA), Saudi Arabia
Zitieren
APA
Elmetennani, S., & Oteafy, A. M. A. (2026). Direct Maximum Power Point Identification Based on Explicit I – V Curve Approximation for Photovoltaic Modules in DC Microgrids. IEEE Access, 14, 169724-169739. https://doi.org/10.1109/access.2026.3746515
Vancouver
Elmetennani S, Oteafy AMA. Direct Maximum Power Point Identification Based on Explicit I – V Curve Approximation for Photovoltaic Modules in DC Microgrids. IEEE Access. 2026;14:169724-169739. doi:10.1109/access.2026.3746515
BibTeX
@article{Elmetennani2026,
author = {Elmetennani, Shahrazed and Oteafy, Ahmed M. A.},
title = {Direct Maximum Power Point Identification Based on Explicit I – V Curve Approximation for Photovoltaic Modules in DC Microgrids},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {169724--169739},
doi = {10.1109/access.2026.3746515}
}
EUVIMED