Grid-Impact-Aware Planning of Electric Vehicle Charging Infrastructure for a Tourism-Intensive Island Grid Using Mixed-Integer Optimization and AC Power Flow Assessment

Thi-Minh-Chau Le, Tien-Khai Nguyen, Trong-Nghia Le

IEEE Access · 2026 · 14 · 119449-119466

DOI: 10.1109/access.2026.3718247 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Thi-Minh-Chau Le und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ho Chi Minh City University of Technology and Engineering, Trường Đại học Bách Khoa Hà Nội.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electric vehicle charging station (EVCS) deployment is conventionally framed as a siting-and-sizing problem, yet in tourism-intensive island grids the binding question is whether an optimized layout remains acceptable once embedded in the distribution network. This paper develops a grid-impact-aware planning framework that links simultaneous charging factor (SCF)-based demand conversion, multi-objective mixed-integer programming (MOMIP), bus-level load mapping, AC power-flow assessment, and source-side N-1 contingency screening in one traceable pipeline. A Hybrid strategy, in which Binary Integer Particle Swarm Optimization with Greedy Repair (BIPSO-GR) provides a feasible incumbent for Branch-and-Cut (B&C) refinement, is benchmarked against standalone B&C and BIPSO-GR on a 16-bus, 22 kV feeder under base, source-side N-1, and seasonal/event-driven demand-growth scenarios. Voltage magnitude remains non-discriminating across all cases. The binding factor is the post-contingency hosting-capacity margin (HCM) of the transfer corridor, governed by charger allocation and spatial load concentration. Under source-side N-1 operation, the distributed B&C and Hybrid layouts yield contingency severity index (CSI) values of 18.6% and 16.2%, whereas the concentrated BIPSO-GR layout reaches 57.3%, about 3.1 times the B&C benchmark and 3.5 times the Hybrid value. Under the $1.5\times $ demand-stress case, the Hybrid layout preserves 35.3% HCM, compared with only 5.3% for BIPSO-GR. A ±20% SCF sensitivity confirms that the lower-severity ranking of the distributed layouts is preserved within the tested simultaneity range. These results show that EVCS layouts must be screened for bus-level grid impact and post-contingency thermal security, not for optimization feasibility or voltage compliance alone.

Förderung

  • Ho Chi Minh City University of Technology and Engineering
  • Trường Đại học Bách Khoa Hà Nội

Zitieren

APA

Le, T., Nguyen, T., & Le, T. (2026). Grid-Impact-Aware Planning of Electric Vehicle Charging Infrastructure for a Tourism-Intensive Island Grid Using Mixed-Integer Optimization and AC Power Flow Assessment. IEEE Access, 14, 119449-119466. https://doi.org/10.1109/access.2026.3718247

Vancouver

Le T, Nguyen T, Le T. Grid-Impact-Aware Planning of Electric Vehicle Charging Infrastructure for a Tourism-Intensive Island Grid Using Mixed-Integer Optimization and AC Power Flow Assessment. IEEE Access. 2026;14:119449-119466. doi:10.1109/access.2026.3718247

BibTeX
@article{Le2026,
  author = {Le, Thi-Minh-Chau and Nguyen, Tien-Khai and Le, Trong-Nghia},
  title = {Grid-Impact-Aware Planning of Electric Vehicle Charging Infrastructure for a Tourism-Intensive Island Grid Using Mixed-Integer Optimization and AC Power Flow Assessment},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {119449--119466},
  doi = {10.1109/access.2026.3718247}
}
Kostenlos starten →