Impacts of AIS Temporal Asynchrony on False-Negative Risk in CPA-Based Near-Miss Detection
IEEE Access · 2026 · 14 · 85940-85951
DOI: 10.1109/access.2026.3700121 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Jinwan Park. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Automatic Identification System (AIS) data are widely used for maritime traffic monitoring and near-miss detection. Most detection approaches based on the closest point of approach (CPA) implicitly assume that AIS reports from different vessels are temporally synchronized. However, in real maritime environments, AIS messages are often received at irregular intervals. Despite this, the influence of AIS temporal asynchrony on the reliability of CPA-based near-miss detection has not been systematically investigated. This study investigates how temporal asynchrony in AIS reporting affects CPA-based near-miss detection using real-world AIS encounter data. The distribution of time differences between AIS reports of vessel pairs was analyzed, and detection outcomes were evaluated under multiple temporal synchronization thresholds ( ${\mathrm {DT}}_{\mathrm {MAX}}$ ) through encounter-level analysis. The results show that AIS report time differences exhibit a long-tailed distribution ranging from several seconds to several minutes. To clarify the evaluation framework, false-negative near-miss events refer to encounters detected under the baseline condition without temporal filtering but missed under ${\mathrm {DT}}_{\mathrm {MAX}}$ filtering. Detection experiments indicate that stricter temporal synchronization constraints lead to an increase in missed detections. For example, under a moderate CPA threshold (0.5 NM, 30 min), the false-negative rate relative to the baseline condition increases to approximately 36% when ${\mathrm {DT}}_{\mathrm {MAX}}=60~s$ , but decreases to about 5% when ${\mathrm {DT}}_{\mathrm {MAX}}=240~s$ . These findings demonstrate that AIS temporal asynchrony is a critical factor affecting the reliability of CPA-based near-miss detection under real-world irregular reporting conditions. The results further indicate that ${\mathrm {DT}}_{\mathrm {MAX}}=\mathrm { }240~s$ provides a practical reference point, maintaining 94.2–95.7% detection reliability depending on the CPA threshold. Incorporating temporal synchronization into AIS-based detection algorithms is therefore essential for improving the reliability of maritime traffic monitoring, navigational decision-support systems, and Maritime Autonomous Surface Ships (MASS).
Zitieren
APA
Park, J. (2026). Impacts of AIS Temporal Asynchrony on False-Negative Risk in CPA-Based Near-Miss Detection. IEEE Access, 14, 85940-85951. https://doi.org/10.1109/access.2026.3700121
Vancouver
Park J. Impacts of AIS Temporal Asynchrony on False-Negative Risk in CPA-Based Near-Miss Detection. IEEE Access. 2026;14:85940-85951. doi:10.1109/access.2026.3700121
BibTeX
@article{Park2026,
author = {Park, Jinwan},
title = {Impacts of AIS Temporal Asynchrony on False-Negative Risk in CPA-Based Near-Miss Detection},
journal = {IEEE Access},
year = {2026},
volume = {14},
pages = {85940--85951},
doi = {10.1109/access.2026.3700121}
}
EUVIMED