Fachartikel in der Zeitschrift IEEE Access, 2026. Verfasst von Abdelazim Salem und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: ENET Centre, CEET, VSB-Technical University of Ostrava, 708 00 Ostrava, Czech Republic.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The contributions in this paper consist of two techniques for power flow analysis and optimization algorithm to optimal integration of distributed generation (DG) sources in radial distribution network (RDN). The ${1}^{\textit {st}}$ technique depends on a mathematical representation to create the bus impedance matrix $[{Z}_{bus}]$ based on the RDN configuration. The ${2}^{\textit {nd}}$ technique is the Bus-Grouping Optimization Algorithm for any RDN ( ${BGOA}_{RDNs}$ ) for reducing active and reactive power losses, improving the RDN voltage profile, minimizing the voltage deviation index (VDI) and reducing the annual cost of energy losses through optimal DGs location and sizing. The applicability and effectiveness of the new approach has been verified on the IEEE 33-bus and IEEE 69-bus RDN. It has been observed that the proposed technique method resulted in further improvement in both reducing annual energy losses and saving costs over recent optimization techniques. In the IEEE 33-bus test system, the reduction percentage in active and reactive losses are found to be 65.5% and 65.8% respectively with annual energy cost saving decrement is 65.505%. While in the IEEE 69-bus system, the reduction percentage in active and reactive losses are found to be 69.13% and 65.78% respectively with annual energy cost saving decrement is 69.134%. So, the results of ${BGOA}_{RDNs}$ are better than other techniques.

Förderung

  • ENET Centre, CEET, VSB-Technical University of Ostrava, 708 00 Ostrava, Czech Republic

Zitieren

APA

Salem, A., Flah, A., & Aboraya, A. E. S. (2026). Improved Performance of Electrical Distribution Network With Optimal DG Allocations Applying New Optimization Approach and Power Flow Analysis. IEEE Access, 14, 86723-86737. https://doi.org/10.1109/access.2026.3700024

Vancouver

Salem A, Flah A, Aboraya AES. Improved Performance of Electrical Distribution Network With Optimal DG Allocations Applying New Optimization Approach and Power Flow Analysis. IEEE Access. 2026;14:86723-86737. doi:10.1109/access.2026.3700024

BibTeX
@article{Salem2026,
  author = {Salem, Abdelazim and Flah, Aymen and Aboraya, Amgad El-Sayed Salem},
  title = {Improved Performance of Electrical Distribution Network With Optimal DG Allocations Applying New Optimization Approach and Power Flow Analysis},
  journal = {IEEE Access},
  year = {2026},
  volume = {14},
  pages = {86723--86737},
  doi = {10.1109/access.2026.3700024}
}
Kostenlos starten →